36
36
3) H5 Error - Water temperature error in wool/ delicate course
①
In case water temperature in wool/ delicate course is 45
℃
or higher
②
Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
③
Error display is cleared when turning off/ on power.
4) H6 Error - Abnormality in washing heater
①
Within 15 minutes after heater operation begins;
In case standard temperature is of 42
℃
or lower: If temperature does not increase by 2
℃
or more In
case standard temperature is higher than 42
℃
: If temperature does not increase by1
℃
or more
②
If temperature falls below standard temperature by 2
℃
or more due to re-supply of water, etc.,
standard temperature is reset as the current temperature and error check time of15 minutes is reset.
③
Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
④
Error display is cleared when turning off/ on power.
5) H8 Error - Washing heater overheating
①
In case washing heater temperature increases by 5
℃
or more within 30 seconds when there is no
water in tank, etc.
②
Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
③
Error display is cleared when turning off/ on power.