32
32
6-1. IE (Input Error) - Error in water supply
1) Conditions of Occurrence
①
In case the designated water level is not reached in 5 minutes during water supply or re-supply
2) All LEDs are turned off and 'IE' blinks in18:88 display.
3) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
4) Error display is cleared when turning off/ on power.
6-2. OE (Output Error) - Error in drainage
1) Conditions of Occurrence
①
In case water level does not reach reset point in 10 minutes after drainage starts
2) All LEDs are turned off and 'OE' blinks in 18:88 display.
3) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
4) Error display is cleared when turning off/ on power.
6-3. UE (Unbalance Error)
1) Conditions of Occurrence
①
In case main spin-drying is not reached within 20 cycles of balance spin-drying
②
In case balance spin-drying fails during interim spin-drying, UE occurs as the cycle moves to the
next process.
2) All LEDs are turned off and 'UE' blinks in 18:88 display.
3) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
4) Error mode is cleared by opening door and organizing the laundry in spin-dry chamber, closing door and
pressing start/ temporary stop button. Then, spin-drying begins again.
6-1. Error Display
Summary of Contents for DWD-L1021
Page 5: ...8 B01 B02 B03 B05 B04 B08 B07 B06 B10 B09 B11 B12 B13 B14 3 INLET BOX AS ...
Page 7: ...10 4 CABINET F ASSY C12 C01 C02 C03 C14 C15 C06 C07 C04 C05 C11 C08 C09 C10 C13 1st Model ...
Page 9: ...12 5 DOOR AS C11 C01 C02 C03 C12 C10 C09 C04 C07 C05 C06 C08 2st Model ...
Page 13: ...20 9 CABINET AS F07 F01 F03 F02 F04 F05 F10 F09 F08 F06 F11 F12 F13 ...
Page 21: ...41 DWD LU S ...