6-1. IE (Input Error) - Error in water supply

1) Conditions of Occurrence
     

  In case the designated water level is not reached in 5 minutes during water supply or re-supply

2) All LEDs are turned off and 'IE' blinks in18:88 display.

3) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.

4) Error display is cleared when turning off/ on power.

6-2. OE (Output Error) - Error in drainage

1) Conditions of Occurrence
     

  In case water level does not reach reset point in 10 minutes after drainage starts

2) All LEDs are turned off and 'OE' blinks in 18:88 display.

3) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.

4) Error display is cleared when turning off/ on power.

6-3. UE (Unbalance Error)

1) Conditions of Occurrence
     

  In case main spin-drying is not reached within 20 cycles of balance spin-drying

     

   In case balance spin-drying fails during interim spin-drying, UE occurs as the cycle moves to the 

next process.

2) All LEDs are turned off and 'UE' blinks in 18:88 display.

3) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.

4) Error mode is cleared by opening door and organizing the laundry in spin-dry chamber, closing door and 

pressing start/ temporary stop button. Then, spin-drying begins again. 

 

6-1. Error Display

Summary of Contents for DWD-L1021

Page 1: ... 2009 Caution In this Manual some parts can be changed for improving their performance without notice in the parts list So if you need the latest parts information please refer to PPL Parts Price List in Service Information Center http svc dwe co kr S M No ...

Page 2: ...DWD LD1411 1611 Dimension mm 600 X 645 X 850 Maximum mass of textile kg 9 Kg Unit Weight net gross 78 82 71 75 76 80 69 73 Standard Water Consumption 65 ℓ Spin Speed RPM DWC DWD LU10XX MAX 1000 DWC DWD LU12XX MAX 1200 DWC DWD LD14XX MAX 1400 DWC DWD LD16XX MAX 1600 Operating Water Pressure 0 03MPa 0 8MPa 0 3kgf cm2 8kgf cm2 ...

Page 3: ...6 2 PANEL F AS A01 A02 A03 A04 A09 A10 A11 A12 A13 A07 A06 A14 A18 A17 A16 A15 A08 A05 2st Model ...

Page 4: ... 3613058600 ABS 1 A07 CASE PCB F 36111T1R00 HIPS 1 A08 SCREW TAPPING 7122401611 T2S TRS 1 4x16 MFZN A09 PCB BOARD F 3614348500 FR 1 1 A10 HOLDER LED COURSE 3613058400 HIPS 1 A11 BUTTON DIAL 3616644300 ABS 1 A12 DECORATOR BUTTON DIAL 3611696400 ABS 1 CHROMIUM CILDING A13 BUTTON START 3616644600 ABS 1 A14 BUTTON POWER 3616644500 ABS 1 A15 DECORATOR FILM 36116 P C FILM 1 A16 WINDOW COURSE 3615509400 ...

Page 5: ...8 B01 B02 B03 B05 B04 B08 B07 B06 B10 B09 B11 B12 B13 B14 3 INLET BOX AS ...

Page 6: ...0V VDE BITRON 1 B07 HOSE WATER SUPPLY 3613270900 EPDM ID9 5 OD14 5 WASHING 1 B08 HOSE WATER SUPPLY 3613270900 EPDM ID9 5 OD14 5 PRE WASH 2 B09 CLAMP HOSE 3611205800 100H ID 13 8 W 10 0 0 9T 10 B10 VALVE INLET 3615414820 220 240V 1 WAY HOT PP 1 B11 HOSE WATER SUPPLY 3613270900 EPDM ID9 5 OD14 5 HOT 1 B12 HOSE WATER SUPPLY 3613270900 EPDM ID9 5 OD14 5 STEAM 1 B13 PIPE JOINT I 3614426000 PP 1 B14 Uni...

Page 7: ...10 4 CABINET F ASSY C12 C01 C02 C03 C14 C15 C06 C07 C04 C05 C11 C08 C09 C10 C13 1st Model ...

Page 8: ...OOR O 36122UD800 ABS 1 C05 PROTECTOR GLASS 3618345500 ABS 1 C06 DECORATOR DOOR O 3611695900 ABS 1 C07 HOOK DOOR 3613100900 ZNDC 1 C08 SPRING HOOK 3615115400 SUS304 1 C09 HOOK SHAFT 3613101000 SUS D 3 0 1 C10 FRAME DOOR I 36122UD600 PP 1 C11 HINGE DOOR 3612903800 AL DWD T110R 1 C12 CAP HINGE DOOR 3610916500 POM 4 C13 DOOR GLASS 361A113300 GLASS 1 C14 CASE PUMP 36111T1K00 PP 1 C15 COVER PUMP 3611431...

Page 9: ...12 5 DOOR AS C11 C01 C02 C03 C12 C10 C09 C04 C07 C05 C06 C08 2st Model ...

Page 10: ...1A113300 GLASS 1 C04 FRAME DOOR 1 36122UDD00 PP 1 C05 HINGE DOOR 3612903800 ALDC 1 C06 CAP HINGE DOOR 3610916500 POM 4 C07 SCREW TAPPING 7115402029 T1S FLT 14 4 20 STS430 NATURE C08 HOOK DOOR 3613100900 ZNDC 1 C09 SPRING HOOK 3615115400 SUS 1 C10 KOOK SHAFT 36131101000 SUS 1 C11 CASE SPRING DOOR 3611149300 ABS 1 C12 SCREW TAPPING 7122401611 T2STRS 2 4 6 MFZN ...

Page 11: ...SY UNIVERSAL D26 D23 D22 D25 D24 D20 D18 D17 D19 D16 D15 D10 D21 D11 D04 D07 D05 D06 D08 D03 D01 D02 D43 D32 D46 D38 D45 D50 D47 D48 D49 D36 D35 D37 D40 D28 D30 D27 D29 D31 D34 D09 D13 D14 D12 D44 D42 D41 D33 D39 ...

Page 12: ...L 361A600100 NBR 1 D28 SEALING TUB 3612321601 EPDM L1600 0 10 1 D29 FIXTURE HEATER 3612006700 SUS 1 D30 BEARING INNER 3616303100 6206Z 1 D31 UNIT MOTOR UNIVERSAL 36189L4H00 DC220 50 G J 2P PI340 45T CCA 1 D32 BALANCER WEIGHT LOWER 3616110300 PP D LU1011 3 5KG 1 D33 SPECIAL SCREW 3616029400 SWCH 8 5X30 2 D34 SPECIAL SCREW 3616062800 SWRCH18A 7 4 25 5 2 D35 DAMPER FRICTION 361A700130 60N AKS ST 170 ...

Page 13: ...20 9 CABINET AS F07 F01 F03 F02 F04 F05 F10 F09 F08 F06 F11 F12 F13 ...

Page 14: ...PCB AS 3610PCBL55 C LD1213LHS02 1 MAIN PCB AS 3610PCBL50 C LD1412EFA02 1 MAIN PCB AS 3610PCBL00 D LU1212EFA 1 MAIN PCB AS 3610PCBL51 C LD1212MFA 1 F07 PLATE T 3614541100 SECC 1 2T C LU1011 1 F08 SENSOR PRESSURE 3614825240 DL DW13 AIR INLET 315 1 F09 COVER B 3611431600 0 4T SGCC C LU1011 1 F10 FIXTURE TUB AS 3612007421 6KG CHINA SAMWOO 4 F11 FRAME UPPER 36122UD900 SGCC 1 2T 1 F12 UNIT DRAIN PUMP AS...

Page 15: ...ck S W Open 2 More details When turn on LOCK signal all process is conducting normaly When working starts the PCB displays all the sensor conditions In this case BLDC Motor is not tested In order to test it select spin or rinse 5 2 Continous testing mode 1 Process After pressing Temp option SPIN button simultaniously press POWER button ALL LED On SPIN button ALL LED off L C Lock Close r Motor righ...

Page 16: ...rned off and OE blinks in 18 88 display 3 Error buzzer alarm is sounded for 10 seconds per every 10 minutes 4 Error display is cleared when turning off on power 6 3 UE Unbalance Error 1 Conditions of Occurrence In case main spin drying is not reached within 20 cycles of balance spin drying In case balance spin drying fails during interim spin drying UE occurs as the cycle moves to the next process...

Page 17: ... line test mode 2 Water supply motor is kept on until water level falls below reset 3 All LEDs are turned off and E1 blinks in 18 88 display 4 Error buzzer alarm is sounded for 10 seconds per every 10 minutes 5 Error display is cleared when turning off on power 6 6 E2 Overflow error 1 Conditions of Occurrence In case water level in water tank is above overflow level due to continuous operation of ...

Page 18: ...d for 10 seconds per every 10 minutes 4 Error display is cleared when turning off on power 6 8 E9 Abnormalities in water level sensor 1 Conditions of Occurrence In case water level frequency is of 15KHz or lower and 30KHz or higher during cycle due to abnormalities in water level sensor etc 2 All LEDs are turned off and E9 blinks in 18 88 display 3 Error buzzer alarm is sounded for 10 seconds per ...

Page 19: ... window Error buzzer alarm is sounded for 10 seconds per every 10 minutes Error display is cleared when turning off on power 4 E8 Initial Operation Fail Error In case input signal of Hall IC is abnormal due to problems in motor connection etc Motor operation is stopped and E8 is shown in display window Error buzzer alarm is sounded for 10 seconds per every 10 minutes Error display is cleared when ...

Page 20: ...temperature is higher than 42 If temperature does not increase by1 or more If temperature falls below standard temperature by 2 or more due to re supply of water etc standard temperature is reset as the current temperature and error check time of15 minutes is reset Error buzzer alarm is sounded for 10 seconds per every 10 minutes Error display is cleared when turning off on power 5 H8 Error Washin...