36
6-9. Motor-related Error
1) E5 (DC-Link High Voltage) Error
①
In case DC-link voltage to IPM increases to 450V or higher
②
Motor operation is stopped and 'E5' is shown in display window.
③
Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
④
Error display is cleared when turning off/ on power.
2) E6 (EMG) Error
①
In case current detected with EMG port is of 20A or higher
②
Motor operation is stopped and 'E6' is shown in display window.
③
Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
④
Error display is cleared when turning off/ on power.
3) E7 (Direction) Error
①
In case signal of Hall IC is different from the predicted signal according to direction of rotation
②
Motor operation is stopped and 'E7' is shown in display window.
③
Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
④
Error display is cleared when turning off/ on power.
4) E8 (Initial Operation Fail) Error
①
In case input signal of Hall IC is abnormal due to problems in motor connection, etc.
②
Motor operation is stopped and 'E8' is shown in display window.
③
Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
④
Error display is cleared when turning off/ on power.
6-10. Error in Temperature Sensor
1) H2 Error - Washing temperature sensor open/ short
①
In case washing temperature sensor is defective or not connected
②
Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
③
Error display is cleared when turning off/ on power.
2) H4 Error - Washing temperature sensor overheating
①
In case temperature detected by washing temperature sensor is 95
℃
or higher
②
Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
③
Error display is cleared when turning off/ on power.
Summary of Contents for DWD-L100 Series
Page 10: ...8 B01 B02 B03 B05 B04 B08 B07 B06 B10 B09 B11 B12 B13 B14 3 INLET BOX AS...
Page 12: ...10 4 CABINET F ASSY C12 C01 C02 C03 C14 C15 C06 C07 C04 C05 C11 C08 C09 C10 C13 1st Model...
Page 14: ...12 5 DOOR AS C11 C01 C02 C03 C12 C10 C09 C04 C07 C05 C06 C08 2st Model...
Page 20: ...18 8 DUCT B for dry model E01 E15 E13 E14 E12 E11 E04 E07 E06 E10 E08 E03 E05 E02 E09...
Page 22: ...20 9 CABINET AS F07 F01 F03 F02 F04 F05 F10 F09 F08 F06 1 F06 2 F06 F11 F12 F13...
Page 41: ...39 39 6 WIRINGDIAGRAM DWC LD S...
Page 42: ...40 40 DWD LD S...
Page 43: ...41 DWC LU S...
Page 44: ...42 DWD LU S...