33
MESSAGE
ERROR
CAUSE
SOLUTION
The thermistor dry is an inferior product or broke down.
Change the thermistor dry.
The thermistor dry is not connected normally.
Check the connector of the thermistor dry.
The thermistor wash is an inferior product or broke down.
Change the thermistor wash.
The thermistor wash is not connected normally.
Check the connector of the thermistor wash.
The fan motor does not spin with the proper rpm.
Change the fan motor.
(The fan motor is an inferior product or broke down.)
The thermistor dry is an inferior product or broke down.
Change the thermistor dry.
The heater worked without the water in the tub.
Check the water level.
The thermistor wash is an inferior product or broke down.
Change the thermistor wash.
The water temp. is over 45°C in delicate & wool course.
Change the thermistor wash.
The heater wash dose not work.
Change the heater wash.
(The water temp. doesn't rise over 2°C during 15min.)
The heater dry dose not work.
Change the heater dry.
(The water temp. doesn't rise over 3°C during 8min.)
The heater worked without the water in the tub.
Check the water level and the heater wash.
The drain pump filter is clogged.
Clean the drain pump filter.
The drain pump does not work during spin.
Change the drain pump.
The large amount of detergent was used.
Use the proper amount of detergent.
The drain hose is placed higher than 1m above the floor.
Place the drain hose 1m below the floor
THERMISTOR
(TEMP. SENSOR)
DRY ERROR
H1
THERMISTOR
WASH ERROR
THERMISTOR DRY
OVERHEATING
ERROR
H2
THERMISTOR WASH
OVERHEATING
ERROR
H3
WATER TEMP.
ERROR
HEATER WASH
ERROR
HEATER DRY
ERROR
PUMP
FILTER
ERROR
HEATER WASH
OVERHEATING
ERROR
H4
H5
H6
H7
H8
PFE
Summary of Contents for DWD-E113R
Page 1: ...DRUM WASHING MACHINE DEC 2006 DWD E115R DWD E113R WDE115R001 ...
Page 14: ...11 3 CABINETFASSY 1 PREMIUM TYPE ...
Page 16: ...13 3 CABINETFASSY 2 LUXURY TYPE ...
Page 18: ...15 4 CABINETASSY ...
Page 20: ...17 5 BASEUAS ...
Page 22: ...19 6 TUBASSY ...
Page 24: ...21 7 DUCTBAS DUCTPIPEAS ...