![Daewoo DWD-1211RT Service Manual Download Page 39](http://html1.mh-extra.com/html/daewoo/dwd-1211rt/dwd-1211rt_service-manual_499130039.webp)
34
4. HEATER
1) SPEC. OF HEATER
Part Name
Maker
Power source
Power Consumption
Resistance
Current Density
Temperature fuse
Thermistator
Material
Part Code
heater wash
IRCA
110V
1000W
±
5%
12.1
4.3
144
℃
Combined in heater
SUS430
361280110
heater dry
IRCA
110V
1200W
±
5%
10.08
3.5
128
℃
(exterior)
exterior
INCLOY800
3612801300
1. Temperature fuse
•
If the heater is on without water, because of pressure switch trouble, fire can be occurred.
Temperature fuse prevents this hazard of fire.
•
The heater wash must be submerged in water.
2. The device for overheating prevention of the dry heater
•
Temperature fuse : 128
℃
cut-off type, 250V 15A
•
Thermostat : 150
℃
off 120
℃
on,230V 15A