CP-520
V
Service Manual
36
available on one of the other CVBS inputs.In this condition the connections between the vision IF
amplifier and the synchronisation circuit can be switched on and off by means of the VDX bit.
The VDXEN bit must be set to “1” for this mode.
The vertical synchronisation is realised by means of a divider circuit.
5.2.7 Horizontal and vertical drive
The horizontal drive is switched on and off via the soft start/stop procedure. The soft start
function is realised by means of variation of the TON of the horizontal drive pulses. During the
soft-stop period the horizontal output frequency is doubled resulting in a reduction of the EHT so
that the picture tube capacitance can easily be discharged. In addition the horizontal drive circuit
has a ‘low-power start-up’ function.
The vertical ramp generator needs an external resistor and capacitor. For the vertical drive a
differential output current is available. The outputs must be DC coupled to the vertical output
stage.
The IC has the following geometry control functions:
n
Vertical amplitude
n
Vertical slope
n
S-correction
n
Vertical shift
n
Vertical zoom
n
Vertical scroll
n
Vertical linearity correction. When required the linearity setting for the upper and lower part
of the screen can have a different setting.
n
Horizontal shift
n
EW width
n
EW parabola width
n
EW upper and lower corner parabola correction
n
EW trapezium correction
n
Horizontal parallelogram and bow correction.
When the East-West geometry function is not required (e.g. for 90 picture tubes) the EW output
pin can be used for the connection of the AVL capacitor. This function is chosen by means of the
AVLE bit.
5.2.8 Chroma, luminance and feature processing
Someversionscontaina4H/2H(2D)adaptivePAL/NTSC comb filter. The comb filter is
automatically activated when standard CVBS signals are received.A signal is considered as
“standard signal” when a PAL or NTSC signal is identified and when the vertical divider is in the
modes ‘standard narrow window’ or ‘standard TV norm’.For non-standard signals and for
SECAM signals the comb filter is bypassed and the signal is filtered by means of bandpass and
trap filters.
The chroma band-pass and trap circuits (including the SECAM cloche filter) are realised by
means of internal filters and are tuned to the right frequency by comparing the tuning frequency
with the reference frequency of the colour decoder.
Summary of Contents for DTX-21B4
Page 17: ...CP 520V Service Manual 16 4 1 2 BLOCK DIAGRAM ...
Page 26: ...CP 520V Service Manual 25 Block diagram LA42032 ...
Page 33: ...CP 520V Service Manual 32 5 CIRCUIT DESCRIPTION 5 1 BLOCK DIAGRAM ...
Page 53: ...CP 520V Service Manual 7 Exploded View 52 7 1 DTX 21G2 ...
Page 54: ...CP 520V Service Manual Exploded View 53 7 2 DTX 21B4 ...
Page 55: ...CP 520V Service Manual Exploded View 54 7 3 DTX 21U7 ...
Page 56: ...CP 520V Service Manual 8 Printed Circuit Board 55 8 1 4859813693 OLD PCB ...
Page 57: ...CP 520V Service Manual Printed Circuit Board 56 8 2 4859816393 NEW PCB ...
Page 58: ...CP 520V Service Manual 9 Schematic Diagram 57 ...