Indoor Unit
To check up gas leak, the end of flare nut
on A, B part.
Outdoor Unit
valve on C, D part
7
REFRIGERANT SUPPLEMENT
In case that the length of the refrigerant pipe is over 5m, refrigerant must be supplemented.(max.20m)
But the amount of the supplementary refrigerant is variable according to installing condition, so check the condition be-
fore supplementing refrigerant.
This work must be carried out by qualified employees.
• In case that vertical length is over 10m, install an oil trap on the gas pipes.
PIPE INSULATION AND ISOLATION
To prevent vapor from forming inside the pipes, insulate each pipe with heat-resisting polyethylrne resin.
Following figure shows how to insulate and isolate the refrigerant pipes correctly.
LEAK CHECKUP
ELECTRIC WIRE
PIPE LIQUID
FINISHING TAPE
PIPE GAS
ELECTRIC WIRE
PIPE LIQUID
FINISHING TAPE
PIPE GAS
PIPE INSULATION
PIPE INSULATION
(X)
(O)