15
(1) Cooling Condition (Room Temperature > 22°C)
!
Fan Speed: Super high speed
@
Air discharge direction: Fixed
#
Set temperature: 18°C (Fixed)
$
Operation Mode: Cooling Mode
%
Compressor and Outdoor Fan
Dehumidification Mode
Air Discharge Direction
Auto Mode II(Powerful Cooling)
-1
OFF
ON
(Room temperature-18˚C)
0
1
(1) When you turn on the unit, the flaps move the the position of keeping
the room temperature comfortable.
(2) The air discharge direction procedure is below.
UP/DOWN
ON/OFF
LEFT/RIGHT
ON/OFF
!
Desired temperature < Room temperature
Outdoor Fan, Compressor : ON
Indoor Fan : Low speed
@
Desired temperature Room temperature
Compressor : 3 min/ON, 5 min/OFF
Indoor Fan : 3 min 30 second/ON, 4 min 30 second/OFF
Fan Speed : Ultra low speed
#
Room temperature 18°C
Compressor : OFF
Indoor Fan : 1 min/ON, 7 min/OFF
Fan speed : Ultra low speed
COOLING POSITION
HEATING POSITION
<
>