14
Auto Mode
(1) In Auto Mode
After the indoor fan is operated for 20 seconds in the Auto Mode, the unit will operate automatically by selecting
operating Mode according to the room temperature
(2) Selecting Operating Mode Again
Room temperature meets desired temperature and the compressor stops running over 30 minutes, then the unit
selects operating Mode again.
5 Seconds Time Delay of Indoor Fan Motor
Wnen the speed of indoor fan motor changes, there is a time delay of 5 seconds at each speed step.
ROOM TEMPERATURE
28°C
RT
22°C < RT < 28°C
RT
22°C
OPERATING MODE
Cooling
Dehumidifier
Heating
FLAP POSITION
Cooling Position
Cooling Position
Heating Position
(RT: Room temperature)