21
Defrost Function Chart for Outdoor Condenser
Max Load Heating Operation Diagram
• Note1 : 120sec for 24kBtu Model
• Note2 : The Temperature is over 120°C or 15 minute later.
• Note1 : 30s ON. 120s OFF when the Compressor is OFF.
• Note2 : The Fan is ON when the temperature is below 49°C.
• Note3 : The Temperature is over 60°C and 1 minute later.
Comp
Start
4 Way
OD Fan
ID Fan
40sec
*Note1
15min
*Note2
6sec
6sec
40sec
Return
60
°
C
Temperature (Indoor Evaporator)
57
°
C
49
°
C
38
°
C
ID FAN
* Note1
Monitoring
"Ultra Low"
Set Value
"Hi, Mid, Low"
"Hi"
"Hi"
OD FAN
OFF *Note2
OFF *Note3
COMP