8.8.2. Forced Auto
8.8.2.1 Remote control signal can be received in forced auto mode. When receiving the signals, the
forced auto mode will be canceled and the A/C changes to remote control status and performs
operation as the signals indicates.
8.8.2.2 The system performs control according to the remote control auto mode with a set temperature of
24°c.
8.9 Timer
24 hours timer on or off.
8.10 Protecting Function
8.10.1 Compress with a delay of 3 minutes.
8.10.2 Sensor open and break protection
8.10.3 EEPROM error protection.
8.10.4 Current protection function.
Condition
Indoor
fan
Compressor
Outdoor
fan
Remark
I< I
RESTORE
On
On
On
On
On
Off
Heating mode
I
RESTORE
<I< I
FAN
Low speed
On
On
Cooling mode
I
FAN
<I<I
5MIN
Off
Off
After 5 Minutes
Current up
I
5MIN
<I< I
3SEC
Off
Off
After 3 Seconds
I
5MIN
<I< I
3SEC
Off
Off
After 3 Seconds
I
FAN
<I<I
5MIN
Off
Off
After 5 Minutes
On
On
Off
Heating mode
I
RESTORE
<I< I
FAN
Low speed
On
On
Cooling mode
Current
down
I< I
RESTORE
On
On
On
8.11 Auto restart Function
In case of a sudden power failure, this function automatically sets the unit to previous
settings before the power failure when power returns.
Summary of Contents for DSA-241L
Page 3: ...2 1 Features 1 1Compact design 1 2LED display ...
Page 5: ...4 3 Dimensions 3 1 Indoor unit DSA 241L ...
Page 6: ...5 3 2 Outdoor unit DSA 241L 12 5 ...
Page 7: ...6 4 Refrigeration cycle diagram ...
Page 25: ...24 Exploded View Parts for Model DSA 241L 220 240V 60Hz Indoor Unit ...
Page 27: ...26 Exploded View Parts for Model DSA 241L 220 240V 60Hz Outdoor Unit ...