Note 1)
!
Neither indoor unit nor outdoor unit runs.
Check the following points first. (There are following case in normal operation)
a. Is the timer mode set the "timer ON".
b. Is the timer mode set the "timer-OFF" and the time had passed?
@
Neither outdoor fan nor compressor runs while indoor fan runs.
Check following points first. (There are following cases in normal operation)
a. Is the temperature set point suitable?
b. Has the 3 minutes time guard for compressor operated?
Note 2) Please refer to page 16, Self Diagnostic-function.
◆
DSA-151L/DSA-181L/DSB-181L
1) Error Code 1
!
Check the connector of room air thermistor. (or connecting wire)
@
Check soldering of connecting on control P.C.B. (Error of soldering or short)
#
Check the resistance of room air thermistor.
2) Error Code 3 (Display Emergency mode)
!
When the compressor do not run.
i) Check the voltage between
and
of terminal block.
(Indoor Unit, Outdoor Unit)
ii) Check connecting wire of indoor unit and outdoor unit.
iii) Check relay KI on power P.C.B
@
Check fixing of indoor coil thermistor.
#
Check the GAS LEAKAGE of the pipe.
Y
N
Self-Diagnostic Function
Summary of Contents for DSA-151L
Page 1: ...Manual de servicio Acondicionador de Aire Tipo Split Modelo DSA 181L ...
Page 18: ...17 4 WIRING DIAGRAM DSA 151L OUTDOOR UNIT INDOOR UNIT ...
Page 19: ...18 DSA 181L DSB 181L ...
Page 27: ...2 2 PCB CIRCUIT DIAGRAM ...
Page 28: ...26 ...
Page 36: ...PCBDRIVINGDESCRIPTION ...
Page 49: ...47 3 EXPLODED DIAGRAM Indoor Unit DSA 151L DSA 181L DSB 181L ...
Page 52: ...50 4 EXPLODED DIAGRAM Outdoor Unit DSA 151L DSA 181L ...
Page 55: ...53 DSB 181L u ...
Page 58: ...56 5 CONTROL BOX ASSEMBLY DSA 151L DSA 181L DSB 181L 1 CONTROL BOX ASSY ...