![Daewoo DSA-151L Service Manual Download Page 3](http://html.mh-extra.com/html/daewoo/dsa-151l/dsa-151l_service-manual_497011003.webp)
2
1. SPECIFICATIONS
MODEL
DSA-151L
DSA-181L
DSB-181L
ITEM
Function
Cooling
Class
T
Power Supply
AC 208~230V, 60Hz
AC 208~230V, 60Hz
AC 220~240V, 50Hz
Capacity W
4,300
5,100
5,100
Btu/h 15,500
17,500
17,500
Dehumidification
1.98l/h
2.3l/h
2.3l/h
Running Current
6.6A
8.3A
9.8A
Power Input
1,450W
1,785W
1,950W
Starting Current
42A
44A
46A
Type
Rotary
Rotary
RECIPRO
Model RCA150A001
ECB185211A
CRDQ-0200-PFJ
Capacitor
30µF/400 VAC
Type
Indoor
Cross Flow Fan
Outdoor
Propeller Fan
Capacitor
Indoor
1.2µF/400 VAC
Outdoor
3µF/400 VAC
Motor Model
Indoor
IC-9425DWKH6A
IC-9425DWKH6A
IC-9425DWKC5A
Outdoor
AM12DPD05
AM12DPD05
AM12DPD04
Control
Capillary
Charge Q'ty
1,250g
1,450g
1,150g
Type
Flare
OD Indoor
1/4”(6.35mm)
(Liquid/Suction)
Outdoor
1/2”(12.7mm)
Dimensions
Indoor
1,035 x 322 x 205
Outdoor
800 x 615 x 277
Net Weight
Indoor
11.7Kg
11.7Kg
11.7Kg
Outdoor
43Kg
44Kg
55.8Kg
Electrical
Data
Compressor
Fan
Refrigerant
(R-22)
Connection
◆
DSA-151L/DSA-181L/DSB-181L
Summary of Contents for DSA-151L
Page 1: ...Manual de servicio Acondicionador de Aire Tipo Split Modelo DSA 181L ...
Page 18: ...17 4 WIRING DIAGRAM DSA 151L OUTDOOR UNIT INDOOR UNIT ...
Page 19: ...18 DSA 181L DSB 181L ...
Page 27: ...2 2 PCB CIRCUIT DIAGRAM ...
Page 28: ...26 ...
Page 36: ...PCBDRIVINGDESCRIPTION ...
Page 49: ...47 3 EXPLODED DIAGRAM Indoor Unit DSA 151L DSA 181L DSB 181L ...
Page 52: ...50 4 EXPLODED DIAGRAM Outdoor Unit DSA 151L DSA 181L ...
Page 55: ...53 DSB 181L u ...
Page 58: ...56 5 CONTROL BOX ASSEMBLY DSA 151L DSA 181L DSB 181L 1 CONTROL BOX ASSY ...