PROBLEM
POSSIBLE
CAUSE(S)
CORRECTIVE ACTION
Compressor will not run
1.No electrical power
2.Blown fuse
3.Breaker open
4.Thermal overload opern
5.Pressure switch bad
1.Plugged in? Check fuse/breaker
2.Replace blown fuse.
3.Reset determining why problem
Happened
4.Motor will restart when cool
(approx. 15minutes).
5.Contact Authorized Service Center
Motor hums but cannot run or
runs slowly
1.Low voltage
2.Shorted or open motor
winding
3.Defective check valve or
pressure switch
4.Compressed air in cylinder
1.Check with voltmeter(105v.min)
2.Contact Authorized Service Center
3.Contact Authorized Service Center
4.Turn the AUTO? OFF switch to the OFF
position for 15 sec. then turn to the AUTO
position
Fuses blow/circuit breaker
trips repeatedly
CAUTION!!
NEVER USE AN
EXTENSION
CORD WITH THIS
PRODUCT!
1.Incorrect size fuse circuit
overloaded
2.Defective check valve or
pressure switch
1.Check for proper fuse. Use timedelay
fuse. Disconnect from other electrical
appliances from circuit or operate
compressor on its own branch circuit
2.Contact Authorized Service Center
Thermal overload protector
Cuts out repeatedly
1.Low voltage
2.Clogged air filter
3.Lack of proper
ventilation/room temperature
too high
1.Check with voltmeter(105v.min)
2.Clean filter(see Maintenance section).
3.Move compressor to well ventilated area.
Tank pressure drops when
compressor shuts off
1.Loose connections(fittings
tubing. etc)
2.Open draincock.
3.Check valve leaking
1.Check for air leaks. Use sealing tape on
all leaking connections.
2.Tighten draincock.
3.Disassemble check valve assembly.
Clean or replace.
DANGER!!
DO NOT DISASSEMBLE CHECK
VALVE WITH AIR IN TANK
BLEED TANK FIRST
Excessive moisture in
discharge air
1.Excessive water in tank
2.High humidity
3.Clogged intake filter
1.Drain receiver
2.Move compressor to area of less humidity:
use air line filter
3.Clean or replace filter
Compressor runs continually
1.Defective pressure switch
2.Excessive air usage
1.Replace switch
2.Compressor not large enough to meet
CFM requirement or the air tool
Compressor vibrates.
1.Loose mounting bolts
2.Rubber tank feel
worn/missing
1.Tighten
2.Replace
Air output lower than normal 1.Open draincock
2.Intake filter dirty
3.Connection leaking
1.Tighten draincock