Air Conditioner Service Manual
9. Installation manual
9.1 Information for installation
Connecting pipe
Model
Pipe size(Inch)
Liquid
Gas
TAC-07CHSA
1/4
3/8
TAC-12CHSA
1/4
3/8
1/4
3/8
TAC-18CHSA
TAC-24CHSA
1/4
1/2
1/4
5/8
Mode
Standard length:
m
Refrigerant
piping Max.
length: m
Additional refrigerant
Calculation: ×g=20g/m(A-5m)
TAC-07CHSA
3.0
15
20g/m
TAC-09CHSA
3.0
15
20g/m
TAC-12CHSA
3.0
15
20g/m
TAC-18CHSA
4.0
15
30g/m
TAC-24CHSA
4.0
15
30g/m
Connecting cables
The power cord should be selected according to the following specifications sheet.
Appliance Amps
Wire Size
5
AWG21/0.75 mm
2
10
AWG18/1.0 mm
2
13
AWG15 /1. 5 mm
2
18
AWG14/1.6 mm
2
25
AWG12/2.0 mm
2
30
AWG10/2.5 mm
2
Outdoor unit
In do o r unit
Pi pe length is
15 meters Max.
b
e
l
e
s
s
t
h
a
n
5
m
H
e
ig
h
t
s
h
o
u
ld
Outdoor unit
Indoor unit
Pipe l ength is
15 meters Max.
b
e
l
e
s
s
t
h
a
n
5
m
H
e
ig
h
t
s
h
o
u
ld
TAC-09CHSA
30