48
Category
Specification
Configuration
Type
1/4 Inch Fitting Solenoid Valve
Voltage
AC 220 VOLT 50/60Hz
Electric Current
35mA or less
Rating Time
Continuous
Power Consumption
5.5W or lower
Terminal Angle
R-0˚, J.D-0˚, C-135˚
(Clockwise at water inlet)
Fluid in Use
Tap water
Flux(3kgf/cm²)
Work-A : R,C-5L or more,
D-0.3~0.7L
Work-B : R,J,C-5L or more
Fluid Pressure
0.2~8kgf/cm²
Opening and Closing
Speed
1.0 sec or shorter
Max. Temperrature
0~90°C But, applicable pressure
shall not exceed 2kgf/cm² for
water of 70~90°C
Coil Resisitance
5.4kΩ±5%(20℃)
Diaphragm Opreation 1.15mm
1) Specification
2) Operation
If the power supply is connected to the water inlet valve, the rod valve is drawn by the coil's magnetic field to
open the diaphragm hall and push up the diaphragm with water pressure. This leads to open the water flow and
start the water supply. If the power supply is cut off, the coil's magnetic field disappears and the force of internal
spring leads the rod valve to close the diaphragm hall, leading to block the water flow.
3. Specifications, Operation, and Defect Inspection of Inlet Valve [Valve for cold water and softener]
Water inlet
Work-A
Work-B
Sus Filter
#250
Red color(J.D port)