48
1) Remove the screw which secure the control panel, push up two snap fits and draw forward the control panel
assembly.
2) Remove the door open lever from the control panel.
3) Remove four screws which secure the PCB assembly to control panel.
4) Disconnect membrane tail from the connector of the PCB assembly.
5) Detach membrane from the control panel.
6) Remove door open button and button spring from the control panel.
7) Reverse the above steps for reassembly.
6. To remove high voltage capacitor.
1) Remove a screw which secure the grounding ring
terminal of the H.V.diode and the capacitor holder.
2) Remove the H.V.diode from the capacitor holder.
3) Reverse the above steps for reassembly.
• High voltage circuit wiring
7. To remove magnetron.
1) Remove a screw which secure the magnetron.
2) Remove the magnetron.
3) Reverse the above steps for reassembly.
NOTE :
Never install the magnetron without the metallic gasket plate which is packed with each magnetron to
prevent microwave leakage. Whenever repair work is carried out on magnetron, check the microwave
leakage. It shall not exceed 4mW/cm
2
for a fully assembled oven with door normally closed.
Summary of Contents for KOG-371G0S
Page 8: ...7 7 KOG 86AH7S 86AH7P 90AH 495 294 394...
Page 63: ...62 2 KOG 396T1S...
Page 65: ...64 Mesurement point...
Page 67: ...66 2 P C B CIRCUIT DIAGRAM...
Page 71: ...70 Mesurement point...
Page 73: ...72 2 P C B CIRCUIT DIAGRAM...
Page 77: ...76 Mesurement point...
Page 79: ...78 2 P C B CIRCUIT DIAGRAM...
Page 83: ...82 Mesurement point...
Page 85: ...84 2 P C B CIRCUIT DIAGRAM...
Page 88: ...87 Mesurement point...
Page 90: ...89 2 P C B CIRCUIT DIAGRAM...
Page 101: ...100 2 KOG 396T1S 2 KOG 396T1S...