AUTOMATIC DRAINING TIME ADJUSTMENT
This system adjusts the draining time automatically according to the draining condition.
Draining
condition
Good draining
Bad draining
No draining
FUNCTIONAL PRINCIPLE
Drain Time
Less than
10 minutes
More than
10 minutes
Continue draining.
Total drain time = D + 60
(T sec.)
Residual drain time.
The time remembered by micom.
The washer begins spin process after drainage.
Draining time is prolonged.
Program is stopped and gives the alarm.
1) The micom can remember the time from the beginning of drain to reset point when the pressure switc
reaches to "OFF" point.
Movement of the program
Program is stopped and gives the alarm with the
display lamp.
2) In case of continuous draining, residual drain time is determined by micom.
blinked on
D
R
A
I
N
I
N
G
T
I
M
E
t
D1
TRIP POINTS
x
E. LOW
LOW
MID
HIGH
T1 = D 1 + 60 (Sec.)
T2 = D2 + 60 (Sec.) T3 = D3 + 60 (Sec.)
T4 = D4 + 60 (Sec.)
W
A
T
E
R
L
E
V
E
L
Summary of Contents for DWF-7570DP
Page 1: ...Service Manual Programmable Washing Machine DWF 7570DP DAEWOO ELECTRONICS CO LTD...
Page 15: ......
Page 16: ...15...
Page 18: ......
Page 19: ......
Page 21: ......
Page 22: ...21...
Page 23: ......
Page 24: ...O...
Page 26: ...25...
Page 27: ......
Page 28: ......
Page 29: ......
Page 30: ......
Page 31: ......
Page 32: ...31...
Page 33: ...J m...
Page 34: ...j N V C O 2 N...
Page 35: ...N N O N O 2 a z c 3...
Page 38: ...38...
Page 39: ...PARTS DIAGRAM 39...
Page 40: ...40...
Page 41: ...rs...
Page 42: ......