DAEHAN STAR L02 User Manual Download Page 4

User Guide

STAR L02

4

Entire sign or leg does not light 

after complete installation.

Check connection from power supply lead to first module. Make sure polarity of connections 
made at the power supply lead and any jumper wire is correct. Power supply outputs should 
be connected red-to-red and white-to-white.

Check  output  voltage  of  power  supply  using  a  voltmeter. The  output  voltage  should  be 
12.0VDC  ±  0.5VDC.  If  there  is  no  output  voltage,  have  a  licensed  electrician  check  input 
voltage. Make sure power supply is connected correctly and getting primary power. Probably 
AC input wire is connected to ground terminal of power supply. If power supply is connected 
properly and getting primary power and there is still no output voltage, try a different power 
supply.

Still does not light.

If power supply is getting primary power and the modules do not light, there may be a short 
in the secondary wiring. Check all connections and cap all loose wires.

Still does not light.

The primary cause of a portion of a S-LED leg not lighting or lighting intermittently is a bad 
connection or reverse polarity connection between the modules that light and the modules 
that don’t light. Check this connection.

Beginning of a leg lights, but the 

entire leg does not light or lights 

intermittently.

S-LED is designed so if one module fails, it will not cause the entire sign or leg to go out. If one 
module does not light, but all others in the leg do, replace this module with a new one.

One module does not light, but 

all others in the leg light.

Check each run has no more than maximum number of modules. Also ensure that type of the 
extension  wire  from  SMPS  to  the  first  module  is  correct.  If  wires  are  not  thick  enough  to 
transmit current from SMPS, this will cause voltage drop and will dim the modules at the end.

All modules light, but some of 

them are dimmed.

Channel depth is too low, or center distance between modules is too far. Refer to 'LAYOUT 
DENSITY GUIDELINES' for more information.

Dark spots or dimmed spots 

occur.

Covering acrylic is not intended for LED illumination. Use light diffusing acrylic sheets which 
are specially made for LED light source.

Still has spots.

TROUBLE SHOOTING

  

FARD lighting GmbH     Seestrasse 20      D - 14974 Ludwigsfelde OT Genshagen

Tel. +49 - (0)3378 / 2003-0       Fax +49 - (0)3378 / 2003-29

[email protected]       www.fard-lighting.de

Reviews: