3. PNP output wiring diagram

2. NPN output wiring diagram

This figure is an example of NPN double output 7-pin wiring.

NPN

Relay

load

load

butt-joint

Ground wire

(

Shield net)

Yellow Green

(+12~24V

 

DC)

0

V

+

-

 Power

2

3

4

5

6

7

 1

2 3

4 5

6 7

 1

BLUE

 (0V)

BROWN

 (VDC)

WHITE

 (OSSD 1)

GREEN

 (OSSD 2)

BLACK

 (CP)

RED

 (CE)

WHITE

 (OSSD 1)

GREEN

 (OSSD 2)

butt-joint

+12~24V DC

Emitter

Receiver

This figure is an example of PNP double output 7-pin wiring.

Relay

load

load

butt-joint

Ground wire

(

Shield net)

Yellow Green

(+12~24V

 

DC)

0

V

+

-

 Power

2

3

4

5

6

7

 1

2 3

4 5

6 7

 1

BLUE

 (0V)

BROWN

 (VDC)

BLACK

 (CP)

RED

 (CE)

WHITE

 (OSSD 1)

GREEN

 (OSSD 2)

butt-joint

+12~24V DC

PNP

Emitter

Receiver

WHITE

 (OSSD 1)

GREEN

 (OSSD 2)

Summary of Contents for QM Series

Page 1: ...autions Please keep it properly for easy retrieval The speci cations and external dimensions recorded in this manual are subject to change or discontinuation due to product improvements without prior...

Page 2: ...Class 2 SEL V power supply device Use the product 1 sec after supplying power When using separate power supply for the sensor and load supply power to sensor rst When using switching mode power supply...

Page 3: ...itter Red and Yellwo always on LED status Indicator Explain Turns on the power All light paths are connected Status indicator Emitter Receiver Status indicator Blocked number indicator Status indicato...

Page 4: ...E 0V BROWN VDC WHITE OSSD1 GREEN OSSD2 BLACK CP RED CE load load BLUE GND BROWN VDC WHITE OSSD1 GREEN OSSD2 BLACK CP RED CE load BLUE GND BROWN VDC WHITE OSSD1 GREEN OSSD2 BLACK CP RED CE load load BL...

Page 5: ...oad butt joint Ground wire Shield net Yellow Green 12 24V DC 0V Power 2 3 4 5 6 7 1 2 3 4 5 6 7 1 BLUE 0V BROWN VDC WHITE OSSD 1 GREEN OSSD 2 BLACK CP RED CE WHITE OSSD 1 GREEN OSSD 2 butt joint 12 24...

Page 6: ...Name Order separately Model Safety relay QSRN QSRN safety relays have three groups of NO and one group of NC with strong control capabilities They are suitable for various signal monitoring in industr...

Page 7: ...t Emitter Blue Brown 0V 24V NC CP CE shielded wire White Green Black Red YG CE Red CP Black OSSD 1 White OSSD 2 Green Brown 24V Blue 0V shielded wire YG Receiver NC 23 13 33 43 S2 S1 0V 24V 24 14 34 4...

Page 8: ...e Power input When not powered on 8 7 6 5 4 3 2 1 Light curtain input NC NO Power input When powered on 4 4 Wiring diagram of QET 1 light curtain relay Share 8 7 2 4 6 1 3 5 Circuit diagram 4 5 Wiring...

Page 9: ...allation of right angle brackets at both ends Original accessories T screw Model QCA 02 1 Flange nut M6 Model QCA 02 2 Unit mm Unit mm R2 10 R2 M6 10 1 6 17 M6 2 R7 R3 R5 14 R1 R1 14 6 Unit mm Model Q...

Page 10: ...dadisick com sale dadisick com 4 Installation method of side right angle bracket Optional accessories Side mounting bracket Model QCA 05 Unit mm 31 R2 13 6 13 17 4 R3 R2 33 2 47 13 6 13 R3 14 23 R10 U...

Page 11: ...ately Stainless steel bracket installation Model QCA 01 Clip Aluminum round Aluminum arm 33 32 4 10 5 7 R11 R17 5 5 8 5 5 75 9 R3 3 R3 3 11 6 5 2 5 6 5 3 8 6 5 14 14 7 35 90 25 R7 R4 3 14 6 0 8 37 16...

Page 12: ...not with a sensing target before using interval distance 0 5 m Emitter Receiver Emitter Receiver Sensing target Reflecting light Reflecting light Sensing target Floor Wall 3 For protection of interfe...

Page 13: ...itter 1 Receiver 1 Emitter 2 Receiver 2 Emitter 1 Receiver 1 Emitter 2 Receiver 2 Baffle should be installed between 2 sets Emitter 1 Receiver 1 Emitter 2 Receiver 2 Baffle Interval distance adjustmen...

Page 14: ...e higher than the lower edge of the lower die mouth and the top beam of light shall not be lower than the upper edge of the upper die port This involves the selection of the protection height of the p...

Page 15: ...ive measures When the horizontal distance between the light cu ain plane of the photoelectric protection device and the front end of the mold base exceeds 400mm auxilia photoelectric or protective fen...

Reviews: