![DADISICK QM Series User Manual Download Page 15](http://html2.mh-extra.com/html/dadisick/qm-series/qm-series_user-manual_3057395015.webp)
Incorrect installation position
(light curtain is low, human hand can reach out from the top of the light curtain)
Upper mold
Lower mold
Installation distance=Ds
Protection height:H
A. The height position is one of the necessary conditions to ensure that the photoelectric protection device realizes
the protection function, and the height position must be ensured correctly during installation.
B. If the mold is replaced during use, the safety distance and height position must be readjusted according to the
above two requirements.
WARNING
2. Setting of auxiliary protective measures
When the horizontal distance between the light cu ain plane of the photoelectric protection device and the front end
of the mold base exceeds 400mm, auxilia photoelectric or protective fences should be installed to prevent the
operator's body from entering the inside of the light cu ain plane. When it is less than 400mm, safety measures such
as auxilia photoelectric or protective fence can also be taken.
Incorrect installation position
(too far from the die port for people to enter the danger zone)
Protection height:H
Upper mold
Installation distance=Ds
Lower mold
DONGGUAN DADI ELECTRONIC TECHNOLOGY CO., LTD
We rese e the right to make technical changes
2023
-
05
-
29
15
Website:
Email:
www.dadisick.com
sale
@
dadisick
.
com
SAFETY LIGHT CURTAIN USER'S MANUAL