GreenOK - Wireless Thermo-Hygro Monitor 

User’s Manual (Rev 2.0) 

 

7

 

 

1. Instructions 

 
 

z

 

‘GreenOK - Wireless thermo-hygro monitor’ monitors temperature and humidity in 
digital display. 

z

 

Temperature operating range is: in case of using external temperature and 
humidity sensor, -20

 to 80

 and 1% to 99%. And in case of using external 

temperature only sensor, temperature operating range is -40

 to 120

 

z

 

You can set temperature high limit and temperature low limit to allow you monitor 
the temperature condition. 

z

 

GreenOK can be applicable as below. 

▪ 

Green House 

▪ 

Warehouse for fresh foods, refrigerator, cold storage warehouse 

▪ 

Museum, Library, Gallery. 

▪ 

Any Temperature and Humidity controls goods 

▪ 

Building and Homes. 

Summary of Contents for GreenOK

Page 1: ...User s Manual Rev 2 0...

Page 2: ...e correctness of the contents Our products are under continual improvements and we reserve the rights to make changes without prior notice Trademarks All trademarks are the properties of their respect...

Page 3: ...not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular install...

Page 4: ...GreenOK Wireless Thermo Hygro Monitor User s Manual Rev 2 0 4 DOCUMENT HISTORY REVISION DATE COMMENTS 1 0 2003 12 22 1 ST revision created 1 1 2004 01 06 2 0 2005 07 26 GMS 120 REV B1...

Page 5: ...FEATURES 9 3 1 WIRELESS SENSING UNIT BATTERY COVER CLOSED 9 3 2 WIRELESS SENSING UNIT BATTERY COVER OPENED 10 3 3 LOCAL MONITORING UNIT 11 4 WIRELESS SENSING UNIT 12 5 LOCAL MONITORING UNIT 19 6 SETT...

Page 6: ...ing Refer all service to qualified service personnel Servicing your own monitor will void the warranty Contact the service contact information Do not break up or disjoint z Out of order If a problem a...

Page 7: ...nd humidity sensor 20 to 80 and 1 to 99 And in case of using external temperature only sensor temperature operating range is 40 to 120 z You can set temperature high limit and temperature low limit to...

Page 8: ...mperature and humidity and Local Monitoring Unit for displaying and receiving from sensing unit z Maximum 16 Wireless Sensing Units can be monitored simultaneously from a single Local Monitoring Unit...

Page 9: ...GreenOK Wireless Thermo Hygro Monitor User s Manual Rev 2 0 9 3 Major Features 3 1 Wireless Sensing Unit Battery cover closed 1 TX GreenOK WIRELESS THERMO HYGRO MONITOR GMS 120 PUSH...

Page 10: ...s Thermo Hygro Monitor User s Manual Rev 2 0 10 3 2 Wireless Sensing Unit Battery cover opened TX SENSOR ID TEMP HI TX INT TEMP LO OFF ON 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 GreenOK WIRELESS THERMO HYGRO...

Page 11: ...ireless Thermo Hygro Monitor User s Manual Rev 2 0 11 3 3 Local Monitoring Unit MUTE SENSOR ID ALM OFF 1 2 3 4 5 6 7 8 GreenOK WIRELESS THERMO HYGRO MONITOR GMS 220 SENSOR ID HUMIDITY TEMPERATURE SERI...

Page 12: ...on Interval It is an interval that measuring results temperature humidity are transmitted Programmable transmission intervals are 1min 2min 5min 10min Factory default transmission interval is 1 min 5...

Page 13: ...GreenOK Wireless Thermo Hygro Monitor User s Manual Rev 2 0 13 Figure 2 Using the Power Switch...

Page 14: ...Wireless Thermo Hygro Monitor User s Manual Rev 2 0 14 TX SENSOR ID TEMP HI TX INT TEMP LO OFF ON 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 GreenOK WIRELESS THERMO HYGRO MONITOR GMS 120 Figure 3 Setting the Se...

Page 15: ...15 TX SENSOR ID TEMP HI TX INT TEMP LO OFF ON 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 GreenOK WIRELESS THERMO HYGRO MONITOR GMS 120 2min Sensor ID 10min 1min 5min Transmit Interval ON 1 2 3 4 ON 1 2 3 4 ON 1...

Page 16: ...Thermo Hygro Monitor User s Manual Rev 2 0 16 TX SENSOR ID TEMP HI TX INT TEMP LO OFF ON 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 GreenOK WIRELESS THERMO HYGRO MONITOR GMS 120 Figure 5 Selecting the External...

Page 17: ...I ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 30 38 34 40 32 36 28 2...

Page 18: ...TEMP LO ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 10 18 14 20 12 1...

Page 19: ...wer limit or more than the upper limit the LED of monitoring unit blinks on red at 0 5 seconds intervals When monitoring unit can t receive any results from sensing unit over presented interval LED tu...

Page 20: ...nsing unit and monitoring unit can be on the table or on the wall using a loop For desk or table stand up the body on a flat part For wall Hang this product using by loop on the wall 3 Setting up the...

Page 21: ...on Must use the specified alkaline batteries and replace two batteries at a time Do not charge short break up the batteries that could Explosion and cause liquid inside out Dispose of them in an envir...

Page 22: ...rature Sensor GMS 120E Temperature 40 120 3 Resolution Temperature 0 1 Humidity 1 4 Accuracy Temperature 1 0 80 2 20 0 Humidity 3 5 Setting DIP Switch Sensor number 1 2 8 9 10 A 16 G Transmission Inte...

Page 23: ...ution Temperature 0 1 Humidity 1 5 User interface Sensor number LED Temperature LED F Humidity LED Alarm LED Alarm 1 Abnormal Temperature Alarm 2 Transmission Failure Sensor rotate switch Mute button...

Page 24: ...eenOK Wireless Thermo Hygro Monitor User s Manual Rev 2 0 24 Tel 82 31 777 5432 Fax 82 31 777 5436 www dadamMicro com 719 Keumkang Hightech Valley 133 1 Sangdaewon1 dong Jungwon gu Sungnam 462 807 Kor...

Reviews: