Before carrying out any operations with the unit,  

carefully read this instruction manual, and keep it 

with cure for future reference.

It  contains  important  information  about  the 

installation, usage and maintenance of the unit.

SAFETY

General instruction

• 

The products referred to in this manual con-

form to the European Community Directives 

and are therefore marked with  .

• 

The unit is supplied with hazardous network 

voltage  (230V~).  Leave  servicing  to  skilled 

personnel  only.  Never  make  any  modifica-

tions  on  the  unit  not  described  in  this  in-

struction manual, otherwise you will risk an 

electric shock.

• 

Connection must be made to a power supply 

system  fitted  with  efficient  earthing  (Class  I 

appliance  according  to  standard  EN  60598-

1). It is, moreover, recommended to protect 

the  supply  lines  of  the  units  from  indirect 

contact and/or shorting to earth by using ap-

propriately sized residual current devices.

• 

The connection to the main network of elec-

tric  distribution  must  be  carried  out  by  a 

qualified  electrical  installer.  Check  that  the 

main  frequency  and  voltage  correspond  to 

those for which the unit is designed as given 

on the electrical data label. 

• 

This  unit  is  not  for  home  use,  only  profes-

sional applications.

• 

Make  certain  that  no  inflammable  liquids, 

water or metal objects enter the fixture.

• 

Do not dismantle or modify the fixture.

• 

All work must always be carried out by quali-

fied technical personnel. Contact the nearest 

sales  point  for  an  inspection  or  contact  the 

manufacturer directly.

• 

If the unit is to be put out of operation defini-

tively, take it to a local recycling  plant for a 

disposal which is not harmful to the environ-

ment.

SICUREZZA

Avvertenze generali

• 

I prodotti a cui questo manuale si riferisce sono 

conformi  alle  Direttive  della  Comunità  Euro-

pea e pertanto recano la sigla  .

• 

Il dispositivo funziona con pericolosa tensione 

di  rete  230V~.  Non  intervenire  mai  al  suo  in-

terno al di fuori delle operazioni descritte nel 

presente manuale; esiste il pericolo di una sca-

rica elettrica.

• 

È  obbligatorio  effettuare  il  collegamento  ad 

un impianto di alimentazione dotato di un’ef-

ficiente messa a terra (apparecchio di Classe I 

secondo  norma  EN  60598-1).  Si  raccomanda, 

inoltre, di proteggere le linee di alimentazione 

delle unità dai contatti indiretti e/o cortocircui-

ti verso massa tramite l’uso di interruttori diffe-

renziali opportunamente dimensionati.

• 

Le  operazioni  di  collegamento  alla  rete  di 

distribuzione  dell’energia  elettrica  devono 

essere  effettuate  da  un  installatore  elettrico 

qualificato. Verificare che frequenza e tensione 

della rete corrispondono alla frequenza ed alla 

tensione per cui l’unità è predisposta, indicate 

sulla targhetta dei dati elettrici. 

• 

L’unità  non  per  uso  domestico,  solo  per  uso 

professionale.

• 

Evitare che nell’unità penetrino liquidi infiam-

mabili, acqua o oggetti metallici.

• 

Non  smontare  e  non  apportare  modifiche 

all’unità.

• 

Tutti  gli  interventi  devono  essere  sempre  e 

solo effettuati da personale tecnico qualifica-

to. Rivolgersi al più vicino centro di assistenza 

tecnica autorizzato.

• 

Se si desidera eliminare il dispositivo definiti-

vamente,  consegnarlo  per  lo  smaltimento  ad 

un’istituzione locale per il riciclaggio.

WARNING!

Prima  di  effettuare  qualsiasi  operazione  con 

l’unità,  leggere  con  attenzione  questo  manuale 

e  conservarlo  accuratamente  per  riferimenti 

futuri.  Contiene  informazioni  importanti  riguardo 

l’installazione, l’uso e la manutenzione dell’unità.

ATTENZIONE!

Summary of Contents for LIVE series

Page 1: ...LIVE series ACTIVE PASSIVE LOUDSPEAKERS EN IT Manuale Utente User Manual...

Page 2: ...nel presente manuale di istruzioni Tutte le revisioni e gli aggiornamenti sono disponibili nella sezione Manuali sul sito www musiclights it All rights reserved by Music Lights S r l No part of this...

Page 3: ...n 3 3 Subwoofer panel active version 3 4 Loudspeaker panel passive version Technical specification Brief notes on acoustics Warranty Sicurezza Avvertenze generali Attenzioni e precauzioni per l instal...

Page 4: ...posal which is not harmful to the environ ment SICUREZZA Avvertenze generali I prodotti a cui questo manuale si riferisce sono conformi alle Direttive della Comunit Euro pea e pertanto recano la sigla...

Page 5: ...paese di impiego il cui produttore ne di chiari e ne garantisca la portata Non usare un solo accessorio per la sospen sione ad esempio una sola catena ma al meno due di portata adeguata In caso di Wa...

Page 6: ...ia ogni obbligo di risarcimento per danni diretti o indiretti even tualmente derivanti dalla difettosit suspensionforhangingspeakers forexample one chain always use at least two of them and make sure...

Page 7: ...oltre la serie LIVE presenta due sub woofers amplificati in configurazione band pass realizzati in multistrato di betulla e con vernice antigraffio 1 INTRODUCTION DAD LIVE series is made up of loudspe...

Page 8: ...ano verticale rispetto al punto di ascolto fondamentale in quanto evita rotazio ni di fase indesiderate delle onde acustiche nella zona di sovrapposizione queste possono causa re una risposta in frequ...

Page 9: ...EAKERS POSITION HORN POSITION H TOTAL COVERAGE HxV LIVE8 8A 30 90 120 x 60 40 90 130 x 60 30 60 90 x 90 40 60 100 x 90 LOUDSPEAKERS LOUDSPEAKERS POSITION HORN POSITION H TOTAL COVERAGE HxV LIVE10 10A...

Page 10: ...sizionare lo stativo su una superficie piana e non sdrucciolevole Per rendere stabile lo stativo allargare al mas simo i piedini 2 2 WALL MOUNTING Take care when choosing the place for the loudspeaker...

Page 11: ...re l effetto di altri carichi ad esempio il vento nelle installazioni all aperto 2 4 SUSPENDED INSTALLATION LIVE series cabinets may be hanged using com patible eye bolts M6 M8 and the points hook ing...

Page 12: ...Diffusore attivo biamplificato con mixer integrato 2ch 1 mic 1 line con regolazioni indipendenti 3 CONNECTIONS AND CONTROLS 3 1 LOUDSPEAKER PANEL CONNECTION ACTIVE VERSION LIVE8A 10A Active biamplifie...

Page 13: ...chiede la sostituzione del fusibile di protezione ed riservata a personale qualificato POWER Interruttore di accensione spegnimen to del diffusore PRESA IEC DI ALIMENTAZIONE Presa per il cavo di colle...

Page 14: ...vo biamplificato con controllo toni e mixer integrato 3ch 2 mic 1 line con regola zioni indipendenti 3 2 LOUDSPEAKER PANEL CONNECTION ACTIVE VERSION LIVE12A 15A Active biamplified loudspeaker with bui...

Page 15: ...esta operazione richiede la sostituzione del fusibile di protezione ed riservata a personale qualificato POWER Interruttore di accensione spegnimen to del diffusore PRESA IEC DI ALIMENTAZIONE Presa pe...

Page 16: ...LIVE series 16 EN IT Esempio Example Fig 8 3 3 PANNELLO DI CONNESSIONE SUBWOOFER VERSIONE ATTIVA LIVE12A 15SA 18SA 3 3 SUBWOOFER PANEL CONNECTION ACTIVE VERSION LIVE12A 15SA 18SA...

Page 17: ...ervata a personale qualificato POWER Interruttore di accensione spegnimen to del diffusore PRESA IEC DI ALIMENTAZIONE Presa per il cavo di collegamento alla rete elettrica com prendente l alloggiament...

Page 18: ...to in pa rallelo di un ulteriore diffusore passivo 3 4 LOUDSPEAKER PANEL CONNECTION PASSIVE VERSION LIVE8 10 12 15 15S 18S Speakon connectors 4p connection for audio input amplified and paralleled con...

Page 19: ...10 woofer 2 6 coil 10 woofer 2 6 coil High frequency 1 driver 1 3 coil 1 driver 1 3 coil 1 driver 1 3 coil 1 driver 1 3 coil Input sensitivity 2dBu 0 6Vrms adjust able 94dB 1W 1m 2dBu 0 6Vrms adjust a...

Page 20: ...fer 3 coil High frequency 1 driver 1 7 coil 1 driver 1 7 coil 1 driver 1 7 coil 1 driver 1 7 coil Input sensitivity 2dBu 0 6Vrms adjust able 98dB 1W 1m 2dBu 0 6Vrms adjust able 98dB 1W 1m Max SPL Cont...

Page 21: ...djustable 2dBu 0 6Vrms adjustable 96dB 1W 1m 2dBu 0 6Vrms adjustable 96dB 1W 1m Max SPL Cont Peak 118 126dB 124 130dB 124 130dB 124 130dB 124 130dB Xover Freq LPF 80 165Hz adjust able 80 165Hz adjust...

Page 22: ...ie o in parallelo Collegare in serie due altopar lanti significa unire un terminale positivo ed uno negativo dei due e collegare all amplificatore i BRIEF NOTES ON ACOUSTIC Diffusing sound into an env...

Page 23: ...un amplificatore con potenza RMS pari alla potenza AES del diffusore facendo comunque attenzio ne a non fornire un segnale di ampiezza tale da portare troppo spesso in clipping l amplifica ance value...

Page 24: ...r s input sensitivity as displayed on the master outputVU meter tore La potenza di breve termine IEC268 5 la potenza che il diffusore pu sopportare per un brevissimo intervallo di tempo Corrisponde a...

Page 25: ...esempio Ray Dolby RMS Root mean square rms La sigla si riferi sce al pi comune metodo matematico atto a definire l effettivo voltaggio o corrente di un on da di corrente alternata Il nome deriva dal...

Page 26: ......

Page 27: ...conseguenti sono a carico del possessore dell apparecchio A tutti gli effetti la validit della garanzia avallata unicamente dalla presentazione del certificato di garanzia The guarantee covers the un...

Page 28: ...ate Data acquisto FORM TO BE FILLED IN AND MAILED CEDOLA DA COMPILARE E SPEDIRE FORM TO BE FILLED IN AND KEPT CEDOLA DA COMPILARE E CONSERVARE PROV ZIP CODE C A P MODEL MODELLO SERIAL N SERIE N Purcha...

Page 29: ......

Page 30: ......

Page 31: ......

Page 32: ...0 fax 39 0771 721955 www musiclights it info musiclights it Music Lights S r l entertainment technologies ISO 9001 2008 Certified Company 2012 Music Lights S r l DAD un brand di propriet della Music L...

Reviews: