background image

3

2

36" (914mm) Recommended

30" (762mm) Min.

25"

(635mm)

30 1/16"

(764mm)10"

(254mm)

14"

(356mm)

Hood

30" (762mm)

Min.

6" (152mm) Min.

to combustible side

walls above the range

(both sides)

13"

(330mm)

Max.

1

10"

(254mm)

Top of 

finished

counter

Vertical

combustible

surface

18" (457mm)

Min.

Overall Cabinet Dimension and Clearance to Combustible Surfaces

Downdraft ERV30 with Slide-In, Self-Rimming Installation using 3” Side Panels (Model No. AESP03), Backguard Removed.

(RSD, RSE and MRE Models Only)

Top View

Slide-In, Self-Rimming Installation using 3” Side Panels (Model No. AESP03), Backguard Removed. (All Models)

Top View

Overall Dimensions

RSD30 Overall Dimensions (Dual Fuel)

Isometric View

RSE30/MRE30 Overall Dimensions (All Electric)

Isometric View

(RSE Shown)

Utilities may be located:

1.  In the lower left corner of the adjacent right 

cabinet. (Recommended)

2.  Alternate location, in the lower right corner 

behind the range. (Note: Some building 

departments do not permit concealing gas 

valves behind appliances.)

Contact your local building department to verify 

compliance with local code interpretation.

1/4" (6mm)

Min. flat ledge

28 11/16" (729mm)

11/16"

(17mm)

29 5/8" (752mm)

Rear wall

25"

(635mm)

Adjust for backsplash

thickness

13/16" to 4 1/4" 

(21 - 108mm)

Backsplash

Vertical

non-combustible

surface rear wall

27 13/16"

(706mm)

29 1/4" (743mm)

13/32" (10mm)

30 1/16" (764mm)

Countertop overhangs cabinet

6" (152mm) Min.

to combustible side

walls above the range

(both sides)

27 7/8" (708mm)

Adjust for backsplash

over 3/4" thick

from 13/16" to 3 13/16" 

(21 - 97mm)

Backsplash

thicker than

3/4" (19mm)

1/4" (6mm)

Min. flat ledge

Vertical

non-combustible

surface rear wall

2 13/16"

(71mm)

Summary of Contents for Preference RSD30

Page 1: ...ge 2 STEP 5 Cabinet and countertop preparation Page 2 3 STEP 6 Overall dimensions Page 3 4 STEP 7 Installing the anti tip bracket Page 4 STEP 8 Removing the oven door Page 4 STEP 9 Removing the kick p...

Page 2: ...must not be used in combination with surface countertop ventilation systems The use of an overhead hood or Dacor Raised Vent is recommended for ventilation 8 This appliance must be installed with the...

Page 3: ...by a qualified electrician 3 If the appliance is connected to a 120 208 volt power supply preheat times and cavity temperature recovery times will be increased slightly Gas and Electrical Rough In Loc...

Page 4: ...ometric View RSE Shown Utilities may be located 1 In the lower left corner of the adjacent right cabinet Recommended 2 Alternate location in the lower right corner behind the range Note Some building...

Page 5: ...nce require an anti tip device Before installing the range you must locate and secure the anti tip bracket to the floor When the range is slid into position in the cutout the left rear leveling leg sl...

Page 6: ...und per square inch NOTE The gas pressure regulator is pre set at the factory for the type of gas intended for use with the appliance Verify that the appliance is compatible with the type of gas avail...

Page 7: ...be steady and quiet It will also have a sharp blue inner cone that will vary in length proportional to the burner size Verify Proper Operation for Electric Ranges RSE and MRE Before beginning the test...

Page 8: ...Web Site www dacor com For a Dealer Service 800 772 7778 Corporate Phone 800 793 0093...

Reviews: