background image

2

Verifying the Package Contents

If any item is missing or damaged, please 

contact your dealer immediately. Do not install a 

damaged or incomplete appliance.

All Ranges

•  Use & Care Manual

•  Anti-tip Bracket

•  Broiler Grill and Pan

•  Oven Racks

Gas Ranges Only

•  Ignitor Cleaning Kit

•  Burner Ring Set

•  Grate/Burner Cap Pack

•  Simmer Plate

Electric Ranges Only

•  Razor Blade Scraper

•  Cooktop Cleaning Cream

Gas Supply Requirements

Check your local building codes for the proper 

method of installation. In the absence of local 

codes, this appliance should be installed in 

accordance with the National Fuel Gas Code 

ANSI Z223.1. Be certain that the appliance 

being installed is correct for the gas service 

being provided.

WARNING:

This appliance must be installed 

by a licensed plumber or gas 

fitter when installed within the 

Commonwealth of Massachusetts.

Dacor

Model 

Number

Dedicated 

electrical

circuit required

Total

connected

load

Gas type

Manifold

pressure

Min. gas

supply

pressure

RSD30

240VAC, 4-wire,

60Hz, 30A

5.8kW (24A)

Natural

4” water

column

5” water

column

RSD30LP

Liquid Propane

10” water

column

11” water

column

RSE30

240VAC, 4-wire,

60Hz, 50A

11.1kW (46A)

N/A

N/A

N/A

MRE30

N/A

N/A

N/A

Gas and Electrical Requirements

Electrical Power Supply 

Requirements

It is the owner’s responsibility to ensure that 

the electrical connection of this appliance 

is performed by a qualified electrician. The 

electrical installation, including minimum supply 

wire size and grounding, must be in accordance 

with the National Electric code ANSI/NFPA 70-

1993* (or latest revision) and local codes and 

ordinances. 

*A copy of this standard may be obtained from:

National Fire Protection Association

1 Batterymarch Park

Quincy, Massachusetts 02269-9101

The correct voltage, frequency, and amperage 

must be supplied to the appliance from a 

separate, grounded, circuit that is protected by a 

properly sized circuit breaker or time delay fuse. 

Refer to the data plate, and/or the Table above, 

for gas supply requirements.

WARNING:

If the gas or electric service 

provided does not meet the 

product specifications, do not 

proceed with the installation. 

Call the selling dealer, the gas 

supplier, or a licensed electrician.

NOTES:

1.  The power supply must 

be properly polarized. 

Reverse polarity will result in 

continuous sparking of the 

electrodes, even after flame 

ignition.

2.  If there is any doubt as to 

whether the power supply 

is properly polarized or 

grounded, have it checked by 

a qualified electrician.

3.  If the appliance is connected 

to a 120/208 volt power supply, 

preheat times and cavity 

temperature recovery times 

will be increased slightly.

Gas and Electrical Rough-In 

Locations

NOTE:

The shaded areas shown in 

the illustrations, denotes the 

location of the gas stub and the 

electrical junction box/receptacle. 

These are suggested locations. 

For replacement purposes, the 

location of the existing utilities 

may be utilized provided that they 

do not interfere with the sides 

or rear of the range. Verify that 

local building codes will permit 

installing the gas valve behind the 

range.

A manual shut off valve must be installed in the 

gas piping, external to the appliance, for the 

purpose of turning on or shutting off gas to the 

appliance. Plan the location of the range and the 

gas supply to allow access to the valve when 

the unit is installed. Access to the remote circuit 

breaker panel/fuse box, with the range in place, 

must also be allowed for in the installation. Any 

openings in the wall behind the appliance and in 

the floor under the appliance must be sealed. 

Both the gas supply piping and shut-off valve, 

and the electrical junction box/receptacle 

must be located so they do not interfere with 

the range when it is installed. In addition, the 

junction box must be located so the range 

can be removed for service when the conduit 

supplied with the unit is attached to the junction 

box. Do not lengthen the conduit or wiring 

provided with the range. 

All dimensions shown are based on standard 

American cabinets 36 inches (914mm) high 

at the finished countertop by 24 inches 

(610mm) deep, with a 25 inch (635mm) overall 

countertop depth. When installing the range 

into nonstandard cabinets, minimum clearances 

shown in the diagrams must be maintained.

Carefully check the location where the range is 

to be installed. For best performance, the range 

should be placed away from drafts that may be 

caused by doors, windows and HVAC outlets.

Cabinet and Countertop Preparation

NOTES:

1.  If cabinet storage space is to 

be provided directly above 

the range, the risk of personal 

injury may be reduced by 

installing a ventilating hood 

that projects horizontally a 

minimum of 5 inches beyond 

the face of the cabinets. 

2.   The range may be installed 

flush to the rear wall. We 

recommend installing a non-

combustible material on the 

rear wall above the range 

and up to the vent hood. It 

is not necessary to install 

non-combustible materials 

behind the range below the 

countertop height.  

3.   The minimum distance from 

the sides of the range above 

the countertop to combustible 

side walls must be at least 6 

inches.

Summary of Contents for Preference RSD30

Page 1: ...ge 2 STEP 5 Cabinet and countertop preparation Page 2 3 STEP 6 Overall dimensions Page 3 4 STEP 7 Installing the anti tip bracket Page 4 STEP 8 Removing the oven door Page 4 STEP 9 Removing the kick p...

Page 2: ...must not be used in combination with surface countertop ventilation systems The use of an overhead hood or Dacor Raised Vent is recommended for ventilation 8 This appliance must be installed with the...

Page 3: ...by a qualified electrician 3 If the appliance is connected to a 120 208 volt power supply preheat times and cavity temperature recovery times will be increased slightly Gas and Electrical Rough In Loc...

Page 4: ...ometric View RSE Shown Utilities may be located 1 In the lower left corner of the adjacent right cabinet Recommended 2 Alternate location in the lower right corner behind the range Note Some building...

Page 5: ...nce require an anti tip device Before installing the range you must locate and secure the anti tip bracket to the floor When the range is slid into position in the cutout the left rear leveling leg sl...

Page 6: ...und per square inch NOTE The gas pressure regulator is pre set at the factory for the type of gas intended for use with the appliance Verify that the appliance is compatible with the type of gas avail...

Page 7: ...be steady and quiet It will also have a sharp blue inner cone that will vary in length proportional to the burner size Verify Proper Operation for Electric Ranges RSE and MRE Before beginning the test...

Page 8: ...Web Site www dacor com For a Dealer Service 800 772 7778 Corporate Phone 800 793 0093...

Reviews: