(C) RECIRCuLATING: Non-Vented, Ductless Operation

1. Remove and save 4 fan cover screws and fan cover bracket 

as shown in Fig. 6.

2. Remove hood fan unit. See Fig. 7.
3. Rotate hood fan unit/end-over-end, then rotate it 90˚ (1/4 turn) 

so that exhaust ports faces toward front of oven unit. The fan 

blades should be visible through the openings facing toward 

the front of the oven.

4. Replace hood fan unit into oven unit as shown in Fig. 11.
5. Put the lead wire into the box.
6. Replace the fan cover bracket. If the cover does not fit properly, 

the hood fan unit is improperly placed. Check steps 3 and 4 

again.

7. Attach the fan cover bracket to the oven unit with 4 existing 

screws as shown in Fig. 9.

NOTE: 

The exhaust damper assembly is not required for  recirculat-

ing exhaust.

CHARCOAL FILTER 

Charcoal Filter is used for non-vented, recirculated installation. The 

filter should be changed every 6 to 12 months depending on use.
1. Disconnect power to the oven at the circuit breaker panel or 

by unplugging. 

2. Remove 2 screws that secure louver.
3. Pull the louver away from the oven.
4. Slide charcoal filter into position on support tabs.
5. Push louver back into place and gently snap tabs into place by 

hand and replace the 2 screws to secure louver.

Hood Fan Unit

Fan Cover Bracket

Mounting Plate

(back side)

Figure 11

Louver

Oven light

Charcoal filter

Screw

Screw

Summary of Contents for PCOR30

Page 1: ...the gaps Wall construction should be a minimum of 2 x 4 wood studding and 3 8 or more thick dry wall or plaster lath The mounting surfaces must be capable of supporting a weight of 110 pounds the oven...

Page 2: ...ection procedures 4 HOOD EXHAUST DUCT When the hood is vented to the outside a hood exhaust duct is required All ductwork must be metal Do not under any cir cumstances use plastic duct work Check that...

Page 3: ...h 4 3 Top Cabinet Screw 5 x 60 mm 2 4 Flat Washer 30 mm diameter 2 5 Grommet 1 6 Tapping Screw 4 x 12 mm 1 7 Exhaust Damper Assembly 1 8 Deflector 1 9 Mounting Plate 1 The installation hardware items...

Page 4: ...nd save 4 screws that hold fan cover in place Remove fan cover bracket as shown in Fig 6 2 Remove hood fan unit carefully and slip wires out of wire box Rotate hood fan unit 90 so that exhaust ports a...

Page 5: ...rly placed Check steps 3 and 4 again 7 Attach the fan cover bracket to the oven unit with 4 existing screws as shown in Fig 9 NOTE The exhaust damper assembly is not required for recirculat ing exhaus...

Page 6: ...appropriate and put the toggle nuts onto the toggle bolts See Fig 12 Refer to instructions in wall template 3 Position the mounting plate with the toggle bolts attached at the wall location and inser...

Page 7: ...ward In the case of a non recessed bottom in the top cabinet the hole for the cord may need to be enlarged Remove the carton portions 6 Tighten the two unit mounting screws located in the grease filte...

Page 8: ...the installation instructions and the wall and top cabinet templates 2 Plug in the power cord 3 Keep the use and care manual MOUNTING DEFLECTOR Secure the deflector with 3 tapping screws 4 x 12mm pac...

Reviews: