Removing Anti-Grease Filter

wARNING:

TO REDUCE ThE RISK OF FIRE, 

ELECTRIC ShOCK, OR INJURY 

TO PERSONS, OBSERVE ThE 

FOLLOwING: 

1.  Before making electrical 

connections to power supply, 

the electrical box must be 

secured in place as indicated 

below.

 

Before installing the appliance, fix the electrical box 

as indicated below:

1.  Remove the central screw.

Removing Central Screw

2.  Lift the electrical plant box.

Lifting Electrical Plant Box

Power Supply Connection

For connection to the power supply refer to the 

following:

BLACK = L line

WHITE = N neutral

GREEN/YELLOW = G ground

A double-pole switch properly rated must be 

installed to provide the range hood power supply 

disconnection.

Connecting Power Supply

Refer above for recommended 

maximum straight lengths of duct to 

provide adequate performance. Refer 

above for recommended sheet metal 

elbows, transitions, and wall cap 

equivalent straight lengths.

NOTE: 

The In Line Blower must be 

located within 60 equivalent feet 

of the hood canopy system.

Model

Number

Duct

Size

Maximum Equivalent Straight Lengths

Internal

ILB8

REMP3

ILB8 & REMP3

MHTW36

8” Round

60’

140’

140’

-

10” Round

50’

100’

100’

-

3 1/4” x 10”

50’

100’

100’

-

Recommended Maximum Straight Lengths

3 1/4" x 10" 90û Elbow

3 1/4" x 10" 45û Elbow

3 1/4" x 10" Wall Cap

3 1/4" x 10"

90û Flat Elbow

Transistion

3 1/4" x 10" to Round

45û Elbow - Round Duct

90û Transistion

3 1/4" x 10" to 8"/10” Round

90û Elbow - Round Duct

15 Feet

7 Feet

2 Feet

20 Feet

8" Diameter - 4 Feet

10" Diameter - 4 Feet

8" Diameter - 3 Feet

10" Diameter - 2 Feet

25 Feet

8" Diameter - 7 Feet

10" Diameter - 5 Feet

Recommended sheet metal elbows, transition, and wall cap equivalent straight lengths

Electrical Power Supply 

Requirements

NOTES:

1.  If the power supply 

requirements shown do 

not agree with those listed 

on the product data plate, 

provide a power source per 

the information found on the 

product data plate. 

2.  If the electrical service 

provided does not meet the 

product specification, or 

does not conform to the NEC 

or local standards, do not 

proceed with the installation.  

Call a licensed electrician to 

correct the electrical service 

before proceeding.

3.  It is the owner’s responsibility 

to ensure that electrical 

installation of this appliance 

is performed by a qualified 

electrician. The electrical 

installation must comply 

Electrical Supply Requirements

120VAC, 60 Hz, 15A Dedicated Circuit

Total Connected Load

 

1.4kW (8A)

The correct voltage, frequency, and amperage 

must be supplied to the appliance from a 

separate, grounded, circuit that is protected by a 

properly sized circuit breaker or time delay fuse. 

Refer to the data plate located on the blower 

housing, inside the filter area, and/or to Table 

below.

with the National Electric 

Code ANSI/NFPA 70-1990 (or 

to latest revision) and local 

codes and ordinances.

4.  Failure to disconnect electric 

power may result in electrical 

shock or fire hazard.

If a connection ductwork composed of two parts 

is used, the upper part must be placed outside 

the lower part. Do not connect the range hood 

exhaust duct air to the same duct air used to 

exhaust hot air or fumes from other appliances 

other than electrical. Before proceeding with the 

assembly operations, remove the anti-grease 

filter(s) so that the unit is easier to handle.