14
Installing the AHT10
12”-/18”-Tall Hood, Top-Vent Configuration and 18”-Tall
Hood, Rear-Vent Configuration
This procedure instructs you how to install the AHT10 tran-
sistion kit for top- and rear-vent configurations.
• Top-vent configuration comprises Models 3012, 3018,
3612, 3618, 4812, and 4818.
• Rear-vent configuration comprises Models 3018, 3618,
4818 with 18-in. height requirement.
• The transition kit does not include the sheet-metal
screws needed for installing the hood.
1. Center the transition kit over the duct collars.
Installation Instructions
Using the Dual-to-Single Transition
Kit #AHT10
On dual-exhaust models, the two 8” duct exhausts can be
transitioned into one 10” duct.
Assemble the Dacor transition kit #AHT10 (sold separately)
before you hang the hood.
This transition kit fits over the
top/rear ventilation exits.
Preparing the AHT10
Create a lip around the transition kit by
bending the bot-
tom edges outward
at right angles, creating a 3/4” flange
around the base.
Bending the Flange (12”-Tall Hoods)
Rear vent only, Models 3012, 3612, 4812
Bending the Flange (18”-Tall Hoods)
• Top vent: Models 3018, 3618, 4818
• Rear vent: Models: 3018, 3618, 4818
IMPORTANT
For rear-vent, 12-in. tall hood configurations (Models
3012, 3612, 4812), leave
one
of the long edges
straight
.
Leave one long edge
straight down (unbent).
(This lip acts as a
bracket.)
Other edges
bent out
All four corners bent outward 90°
Top-Vent
Configuration