background image

2

Important Safety Instructions

• Do not install a damaged appliance. If you receive a dam-

aged appliance, contact your dealer or builder.

• Observe all governing ordinances during planning and instal-

lation. Contact the local building department for details.

• The electrical outlet for the downdraft vent should be

installed by a licensed electrician.

• Do not vent hazardous or explosive materials and vapors

through the unit.

• Use this downdraft vent only as outlined in the User Manual.

The vent is not designed for commercial use.

• The owner should install/repair/replace partts only as

specified in the product literature. A qualified technician

should perform all other service. Contact Dacor Customer

Assurance for examination, repair, or adjustment.

• Keep all packaging away from children.
• For proper operation, install the unit with a cabinet, in-line, or

remote blower. Use only a specified model.

 WARNING

General Safety Precautions

To reduce risk of fire, electric shock, serious injury, or death when using the vent, follow basic safety precautions, including:

• Ensure the vent is unplugged for installation/service.
• The installer must show the customer the outlet so the owner

can unplug the vent as needed.

• Install the vent as instructed in this manual, the Dacor range/

cooktop installation instructions, and the blower installation

instructions.

• Read the User Manual completely before operating the vent.
• Do not tamper with the vent controls.
• Do not let the filters or vent openings become blocked. Do

not let foreign objects be sucked into vent holes.

• Clean the filters and all grease-laden surfaces often to pre-

vent grease fires and maintain performance. Clean the appli-

ance only as specified in the User Manual.

• Do not leave children/pets unattended near the operating

range/cooktop.

• Do not let children play with the downdraft vent.

 WARNING

Electrical Specifications

The downdraft vent comes with a 28” (71.1 cm) power cord 

with a 3-prong plug. Plug it directly into a 3-prong outlet 

meeting the requirements below.
The correct voltage, frequency and amperage must be sup-

plied as specified below. The circuit must be protected by a 

properly sized circuit breaker or time-delay fuse.

Electrical

-

Supply Requirements

A 3-prong outlet connected to a 120 Vac, 60 Hz, 15 Amp. 

grounded, dedicated, single-phase circuit is required. 

• The above specifications are for reference only. If they

conflict with spec’s on the product data label, use the

spec’s on the label.

• The customer must supply 3 conductor wiring/conduit

with minimum 8-Amp current-carrying capacity to sup-

ply power to the blower from the downdraft vent. (See

Installation Specifications

 for details.)

• The owner shall ensure the electrical outlet is installed

by a licensed electrician. The electrical installation must

comply with local ordinances and the latest revision of

the National Electric Code ANSI/NFPA 70 (latest revi-

sion), a copy of which may be obtained from:

National Fire Protection Association 

1 Batterymarch Park 

Quincy, Massachusetts 02269-9101

• The electrical outlet situated so the vent can be

unplugged for service without removing appliances from

the cabinet.

Product Specifications

Summary of Contents for HRV46

Page 1: ...RV48 ER Includes installation instructions for Dacor cabinet blower CABP3 which is an option for the indicated models Part No 113910 Rev E Use these downdraft vents only with approved Dacor appliances...

Page 2: ...nd the local electrical inspector s use Customer Assurance Information All specifications subject to change without notice Dacor assumes no liability for such changes 2018 Dacor all rights reserved Mo...

Page 3: ...an outlet is available for the appliance Do not remove the third ground prong from the power cord use an adapter plug use an extension cord use a damaged power cord Use a ground fault interrupter GFI...

Page 4: ...s become blocked Do not let foreign objects be sucked into vent holes Clean the filters and all grease laden surfaces often to pre vent grease fires and maintain performance Clean the appli ance only...

Page 5: ...for exhaust locations and dimensions Maximum height of downdraft vent must not exceed maximum specified counter height for cooking appliance See installation instructions for cooking appliance Total c...

Page 6: ...down Tolerances 1 16 1 6 mm unless otherwise stated See Pg 9 for exhaust locations dimensions Max height of downdraft must not exceed cooking unit s max specified counter height See cooking unit s ins...

Page 7: ...ust locations dimensions Max height of downdraft vent must not exceed cooking appliance s max specified counter height See cooking appliance s installation instructions IMPORTANT INSTALLER To ensure t...

Page 8: ...f the downdraft vent for connecting blower wiring and strain relief Wire the blower to turn on when the downdraft vent is turned on When installing a remote or in line blower run the blower wiring con...

Page 9: ...de wall Downdraft vent Downdraft vent configured for bottom exhaust Floor Wiring conduit from downdraft to in line blower Cabinet back Front of unit Connection to cabinet blower Blower wiring access h...

Page 10: ...raft vent s air draw Building codes may require makeup air systems with ven tilation systems that move air greater than the specified movement rate CFM Consult a qualified HVAC specialist when designi...

Page 11: ...ne of bottom knock out lines up with vertical center line of chassis On 30 and 36 wide models the vertical center line of bottom knock out is offset 3 Side Exhaust Knock Outs 1 5 8 x 16 Bottom Exhaust...

Page 12: ...onnection center line A Downdraft vent center line Countertop 3 1 4 x 10 duct connection 26 1 4 66 7 cm Exhaust Locations and Side Dimensions for CABP3 Cabinet blower Front Exhaust Dimensions CABP3 Bl...

Page 13: ...e above parts is 15 ft 15 ft 4 ft 2 ft 36 ft The max amount of straight duct that can be used with a REMP16 and the above parts is 60 ft 34 ft 24 ft Equivalent Number of Feet Nominal Duct Elbows and T...

Page 14: ...cooktop Install the down draft vent before installing the range or cooktop 2 Start by loosely attaching the anchoring legs to the studs on the left and right sides of the downdraft vent using the prov...

Page 15: ...ard the 3 lock washers which will be replaced Tilt the cover out and pull up to remove it 2 Peel the backing off of some of the foam tape included with the adapter Attach it to the right and left flan...

Page 16: ...o right left flanges Adapter New label Existing label ILHSF or REMP Series Blower Installation If using a ILHSF or REMP series blower install it according to the blower installation instructions Duct...

Page 17: ...cal Installation CABP3 Cabinet Blower Downdraft Vent Electrical Access Panel Front of unit Wire Colors Black Line L White Neutral N Green Ground Gnd Electrical connection from downdraft vent match Wir...

Page 18: ...aft vent Ensure the downdraft vent supplies power to the blower If the vent will not raise properly or makes a scraping sound check for under counter obstructions If the downdraft vent fails to functi...

Page 19: ...LK WHT WHT Wiring Diagram All Models CABP3 Cabinet Blower Ratings CABP3 Cabinet blower Airflow Nominal 600 CFM Actual 585 6 CFM At zero inches static pressure Performance varies based on duct system c...

Page 20: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com...

Reviews: