Planning the Installation

Location Planning - Enclosed 

Cabinets

Maintain all minimum clearances specified on pages 7 

• 

and 8.

For proper outdoor grill operation, provide a flat, level 

• 

mounting surface with minimum 3/4” thickness.

All models are designed to allow installation in combus-

• 

tible or non-combustible base material structures.

On installations without a LP cylinder tank located 

• 

below the unit, plan the installation so that the gas 
shut-off valve and pressure regulator are accessible 
after the appliance is installed so that gas and power 
can be turned off if service is required. Also, make sure 
the electric plug can be disconnected easily during ser-
vice.

Optional Finish Trim Kits

The optional finish trim can be installed on the countertop 
to finish the sides and back of the countertop opening. The 
stainless steel finish trim can be caulked to the countertop 
and should be secured to the base enclosure with flat head 
screws. Center the trim within the cutout dimensions noted 
in this manual, then utilizing the deck screws along with 
the holes located along the vertical sides of the finish trim, 
install them securely to the base enclosure countertop sub-
straight. Optional Finish Trim Kits.

Enclosed Cabinet Installations with a LP 

Cylinder

When using a LP-gas cylinder, it must be completely 

• 

enclosed, It must also be ventilated by openings on 
the sides, back and floor of the enclosure. Each open-
ing must have a total area of no less than 10 square 
inches (254 square mm).

Plan to install the grill in a base structure that has one 

• 

of the following structural details:

The LP cylinder valve shall be readily accessible 

◊ 

for hand operation. A door on the enclosure to gain 
access to the cylinder valves is acceptable, pro-
vided it is non-locking and can be opened without 
the use of tools.

The enclosure for the LP-gas cylinder shall isolate 

◊ 

the cylinder from the burner compartment to pro-
vide shielding from radiation, a flame barrier and 
protection from foreign materials such as hot drip-
pings.

There shall be a minimum clearance of 2 inches 

◊ 

(51mm) between the floor of the LP-gas cylinder 
enclosure and the ground.

The design of the outdoor cooking enclosure must 

• 

allow the LP-gas cylinder to be connected, disconnect-
ed and the connections inspected and tested outside 
the cylinder enclosure.

Connections which may be disturbed when installing 

• 

the cylinder in the enclosure can be leak tested inside 
the enclosure.

Internal mounting means shall be provided on the out-

• 

door gas grill for mounting the LP-gas supply cylinder. 
If the outdoor grill is not in use, the gas must be turned 
off at the supply cylinder.

Rotisserie mounting

bracket (factory installed)

Junction

Box

Trim frame

(accessory)

3/4" (19mm)

min. to any

material*

1/4"

(6mm)

1 1/4"

(32mm)

10" (254mm) Min. to combustibles

1 1/4" (32mm) Min. to non-combustible

28 1/2" (724mm)

To finished

countertop

23 3/4" (603mm)

24" (610mm)

Junction

Box

Trim frame

(accessory)

3/4" (19mm)

Min. to any

material*

10" (254mm) Min. to combustibles

2" (51mm) Min. to non-combustible

1/4"

(6mm)

23 3/4" (603mm)

24" (610mm)

See page 8 for overall cabinet dimensions

See page 8 for overall cabinet dimensions

oB36, oBs36, oB52 and oBs52

cutout dimensions - Side View

oBSB162 cutout dimensions -

 

side view

Summary of Contents for Epicure OB36

Page 1: ...32 Rev F Tested in accordance with the latest edition of ANSI Z21 58 2006 cSa 1 6 2006 Standard for outdoor cooking gas appliances IN CANADA INSTALLATIONS MUST BE IN ACCORDANCE WITH THE CURRENT CAN CG A B149 1 NATURAL GAS INSTALLATION CODE CAN CG A B149 2 PROPANE INSTALLATION CODE AND OR LOCAL CODE ...

Page 2: ...fuel generates some by products that are on the list of substances which are known by the State of California to cause cancer or reproductive harm California law requires businesses to warn customers of potential exposure to such substances To minimize exposure to these substances always operate this unit according to the use and care manual ensuring you provide good ventilation when cooking with ...

Page 3: ...ation Planning General 6 Location Planning Enclosed Cabinets 7 Location Planning Cart Installations 9 Important Safety Instructions Important Installer In the interest of safety and to minimize prob lems read these installation instructions completely and carefully before you begin the installation process Leave these installation instructions with the customer Customer Keep these installation ins...

Page 4: ...ppliance follow basic safety precau tions including the following Before performing any type of service make sure that the gas supply is turned off at the supply valve and the power plug is disconnected IMPORTANT This appliance is equipped with a three prong grounding electrical plug for protection against possible elec tric shock hazards It must be plugged into a dedicated grounded electrical out...

Page 5: ...erate it play with the controls pull on the handle or touch other parts Do not store items of interest to children on top of or above the appliance Children could be burned or injured while climbing on it Keep the ventilation openings for the LP cylinder free and clear from debris Non stick coatings when heated can be harmful to birds Remove birds to a separate well ventilated area during cooking ...

Page 6: ...673mm 27 686mm 36 914mm 25 1 8 638mm Product Dimensions Planning the Installation 9 1 8 232mm 23 3 4 603mm 26 1 2 673mm 27 686mm 52 1321mm 25 1 8 638mm Total depth from back to front of handles is 30 762mm OB36 and OBS36 OB52 and OBS52 ...

Page 7: ... Overall Height Overall width Total depth from back to front of knobs is 28 5 8 727mm Total height with cover is 12 305mm Door depth 1 4 6mm OBSB162 OBAD SERIES ACCESSORY DOORS OBAD36 SHOWN Model Number Overall Height Overall Width OBAD20 Single door 19 1 2 495mm 21 533mm OBAD36 Dual door 35 7 8 911mm 21 533mm ...

Page 8: ...rm to local codes or in the absence of local codes with either the National Fuel Gas Code ANSI Z223 1 NFPA 54 Natural Gas and Propane Installation Code CSA B149 1 or Propane Storage and Handling Code B149 2 Prevent grill combustion products from being drawn into a building through fresh air inlets The venting system of other than a direct vent appliance must terminate at least 4 feet 1 2m below 4 ...

Page 9: ...ll the grill in a base structure that has one of the following structural details The LP cylinder valve shall be readily accessible for hand operation A door on the enclosure to gain access to the cylinder valves is acceptable pro vided it is non locking and can be opened without the use of tools The enclosure for the LP gas cylinder shall isolate the cylinder from the burner compartment to pro vi...

Page 10: ... 51mm OB S 36 33 1 2 851mm OB S 52 49 1 2 1257mm 6 x 6 152mm x 152mm utility cutout for OBSB162 3 4 19mm Min to any material for ventilation 9 228mm Max OB S 36 36 1 2 927mm OB S 52 52 1 2 1334mm OBSB162 16 1 8 410mm 36 914mm Cutout Dimensions Top View Cutout Dimensions Front View OBAD36 Accessory doors shown Accessory Door Cutout Dimensions Dimension Cutout Width OBAD20 16 3 4 425mm OBAD36 33 1 8...

Page 11: ...nches minimum in front to open and close the cabinet drawers For proper grill and drawer operation use the outdoor grill and cart only on a level surface Side distances exclude optional shelves Above the cooking surface both sides 1 1 4 32mm Min to non combustibles 10 254mm Min to combustibles Above cooking surface behind unit 2 1 2 64mm Min to non combustibles 11 1 4 286mm Min to combustibles wit...

Page 12: ...trical outlet while connecting the gas line to the appliance Do not apply excessive pressure when tightening connections and fittings Do not use plumber s putty or Teflon tape on gas compression connections Doing so can defeat the proper sealing of these fittings Use only approved gas line thread compound or tape to seal gas connections The maximum gas supply pressure to the regulator must not exc...

Page 13: ...11 Installation Instructions D E H L N M P J K F G D D Whole House Natural Gas or LP Regulator LP Cylinder Regulator OBS162 OB36 OBS36 PN 72310 LP Cylinder Regulator OB52 OBS52 PN 101578 ...

Page 14: ...ctrical cord into the utility cut out Center the unit on the cart making sure to line up the 4 threaded mounting holes under the bottom of the grill with the holes in the top of the cart Thread all of the supplied bolts into the bottom of the 5 outdoor grill from inside the cart Tighten the bolts into place Utility Cutout Rotating Wheel Locking Wheel Locking Wheel Tank Shelf Insert power cord into...

Page 15: ...shelf over the pin on 2 the mounting bracket While holding the shelf in place insert the pin on the 3 back mounting bracket into the slot on the back side of the shelf While holding the shelf and back mounting bracket in 4 place attach the back mounting bracket using two 2 of the provided button head fasteners and two 2 lock washers Repeat steps 1 through 4 for the other shelf 5 Installation Instr...

Page 16: ...n the direction of the gas flow towards the grill Connect a 1 2 nipple to the regulator 2 Install an approved flexible gas line from the regulator 3 to the gas line shut off valve Gas Connection Whole House LP Gas Connect the factory supplied regulator assembly to the 1 gas inlet at the back right bottom corner of the appli ance Make sure the arrow on the regulator points in the direction of the g...

Page 17: ... to the right as possible leav ing an opening on the left for the smoker box Insert the smoker box into the opening to the left side 5 of the grills Place the warming rack on the holders on the walls in 6 side the hood 9 Burner Cover 8 Grate 7 Burner Heads Caps 1 Open Hood 6 Warming Rack 2 Drip Tray 3 Flame Spreaders 4 Grills 5 Smoker Box Assemble the Side Burner Some Models Put the burner heads o...

Page 18: ...ly cylinder valve outlet specified as applicable for con nection No 5LP A The cylinder supply system must be arranged for vapor withdrawal and provided with a listed overfill ing prevention device For units that will use a LP cylinder start by making 1 sure the main valve is completely closed Place the tank into the final position within the cabinet 2 or cart Leak Testing warning Do not use a flam...

Page 19: ...been verified Did the installer check the gas supply for leaks Have any problems been noted on the warranty card or during the on line warranty activation Has the war ranty been activated on line or the warranty card filled out completely and mailed With the tank shelf open connect the power cord from 2 the outdoor grill and the warming oven if equipped with one to the electrical outlet on the bac...

Page 20: ...Dacor 1440 Bridge Gate Drive Diamond Bar CA 91765 Tel 800 793 0093 FAX 626 403 3130 www Dacor com ...

Reviews: