background image

Installation Instructions .................................................... 8

Rangetop Installation ....................................................... 8

Gas Line Connection ....................................................... 9

Burner Component Installation ...................................... 10

Burner Knob Installation ..................................................11

Verifying Proper Operation ............................................. 12

Installation Checklist ...................................................... 13

Wiring Diagram ................................................................ 14

Notes................................................................................. 15

Table of Contents

Before You Begin...

Important Safety Instructions .......................................... 1

Important Information About Safety Instructions .............. 1

General Safety Precautions ............................................. 2

Installation Requirements ................................................ 3

Electrical Requirements ................................................... 3

Gas Supply Requirements ............................................... 3

Product Dimensions ......................................................... 3

Cabinet and Countertop Layout ....................................... 4

Cabinet/Cutout Dimensions ............................................. 5

All specifications are subject to change without notice. Dacor

 

assumes no liability for changes to specifications.

Important:

• 

Installer:

 In the interest of safety and to minimize problems, read these installation instructions completely and care-

fully before you begin the installation process. Leave these installation instructions with the appliance.

• 

Customer:

 Keep these installation instructions for future reference and the local building inspector’s use.

© 2014 Dacor, all rights reserved.

CALIFORNIA PROPOSITION 65 WARNING

The burning of gas cooking fuel generates some by-products that are on the list of substances which are known by 

the State of California to cause cancer or reproductive harm. California law requires businesses to warn customers of 

potential exposure to such substances. To minimize exposure to these substances, always operate this unit according 

to the use and care manual, ensuring you provide good ventilation when cooking with gas.

If You Need Help...

If you have questions or problems with installation, contact 

your Dacor

 

®

 dealer or the Dacor Customer Service Team. 

For repairs to Dacor appliances under warranty call the 

Dacor Distinctive Service line. Whenever you call, have the 

model and serial number of the appliance ready. The model 

and serial number are printed on the appliance data plate.

Dacor Customer Service

Phone: (800) 793-0093 ex. 2813 (U.S.A. and Canada) 

Monday — Friday 6:00 

a

.

m

.

 to 5:00 

p

.

m

.

 Pacific Time

Web site:  www.dacor.com

Dacor Distinctive Service (repairs under warranty only)

Phone: (800) 793-0093 ex. 2822 (U.S.A. and Canada)  

Monday — Friday 6:00 

a

.

m

.

 to 5:00 

p

.

m

.

 Pacific Time

Customer Service Information

Product Data Label

•  The product data label contains the model and serial 

number information and the electrical and gas supply 

requirements.

•  It is attached to the bottom of the chassis.

Model Identification
     DYRTP366S/NG/H

SIZE 

(in inches)

GAS TYPE

 

NG =   Natural Gas

 

LP =   Liquid Petroleum  

   (Propane)

ALTITUDE

 

H =  

High Altitude Model, 4000 ft.(1219 m) and up

 

No character = Equipped for low altitude operation

Summary of Contents for DYRTP366

Page 1: ...lation Instructions Discovery Rangetop Models DYRTP366 DYRTP486 Part No 108317 Rev C THIS APPLIANCE HAS BEEN TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI Z21 1 STANDARD FOR HOUSEHOLD GAS APPLI...

Page 2: ...f California to cause cancer or reproductive harm California law requires businesses to warn customers of potential exposure to such substances To minimize exposure to these substances always operate...

Page 3: ...se a fire extinguisher ONLY if You have a Class ABC extinguisher and you already know how to operate it The fire is small and contained in the area where it started The fire department is being called...

Page 4: ...ing tasks expected of a home appliance as outlined in the literature accom panying it This rangetop is not intended for commer cial or laboratory use WARNING General Safety Precautions To reduce the r...

Page 5: ...d in accordance with the National Fuel Gas Code ANSI Z223 1 NFPA 54 The gas service must be installed by a qualified profes sional Be certain that the rangetop being installed is cor rect for the gas...

Page 6: ...ing the rangetop into a lami nated or synthetic countertop radius the corners of the cutout to help avoid cracking Consult the countertop manufacturer s instructions for minimum corner radius reinforc...

Page 7: ...herwise noted Rangetop Model B C DYRTP366 36 91 4 cm 36 91 4 cm 42 106 7 cm DYRTP486 48 121 9 cm 48 121 9 cm 54 137 2 cm Minimum Recommended continued on following pages See note 2 2 See Cabinet Count...

Page 8: ...ng 1 2 5 cm thick mounting platform min Countertop Countertop 1 2 1 3 cm countertop overhang 2 5 1 cm Counterop overhang 1 2 5 cm typical 1 3 8 3 5 cm max 11 7 16 29 1 cm 24 63 5 cm min cabinet depth...

Page 9: ...electrical connections Countertop Countertop 1 2 1 3 cm countertop overhang 2 5 1 cm 11 7 16 29 1 cm C L D D E B C L C L C L 26 5 8 67 6 cm min cabinet depth Counterop overhang 1 2 5 cm typical 1 3 8...

Page 10: ...ainless Steel Cleaner WOK ring Griddle 2 hold down bolts 2 washers for hold down bolts Gas regulator Product literature The rangetop is supplied with two different types of burner caps brass and porce...

Page 11: ...off valve to the rangetop dur ing any gas supply piping system pressure testing equal to or less than 1 2 psi 3 5 kPa For LP gas installations the LP gas tank must have its own high pressure regulator...

Page 12: ...ype color of the supplied burner caps may be used When installing the burner components twist each piece back and forth slightly until it drops completely into place The burners will not operate prope...

Page 13: ...ith the rangetop The knobs for the center burners have the words MAX GRIDDLE on them If not already installed put the knobs with the words MAX GRIDDLE on them onto the inner center burner valve shafts...

Page 14: ...en repeat the test Once the burner lights the control knob can be rotat ed counterclockwise from HIGH to LOW to adjust the flame height progressively When the unit is installed properly the flame will...

Page 15: ...d installed according to these instructions and in accordance with all applicable codes See pages 3 and 4 Has the gas supply inlet pressure been measured to ensure that it does not exceed the maximums...

Page 16: ...ARNESS O O O O O O B B B B B B B B RL BURNER IGNITOR IGNITOR RC BURNER RR BURNER IGNITOR IGNITOR FR BURNER IGNITOR FL BURNER FC BURNER IGNITOR S1 S2 S3 S4 S6 S5 B B B B BLACK WHITE FR LED HARNESS W W...

Page 17: ...15 Notes...

Page 18: ...16 Notes...

Page 19: ......

Page 20: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com...

Reviews: