Verifying burner function
After the cooktop is fully installed, connected, assembled, and plugged in, verify burner
function. Perform this procedure for each burner in turn.
To turn on a cooktop burner
1.
Push in, and turn a burner control
knob to the "Lite" position (flame icon).
A "click-click-click...” indicates the
electronic ignition system functions.
The burner ignites in about 4 seconds ,
after air is purged from the gas line.)
2.
Turn the knob to the desired setting.
(The “clicking” stops; the flame height
changes from HI to LO as you turn the
knob counterclockwise.)
NOTE
If the burner does not light within 4 seconds, turn the knob off and wait one minute
before trying again.
Checking flame quality
All burner flames must be visually checked to assess their quality.
CAUTION
If you want measure the flame, take care to avoid burn injuries.
2
3
1
1.
Soft blue flames
—Normal for natural
gas operation.
2.
Yellow tips on outer cones
—Normal for
LP gas operation.
3.
Yellow flames
—Abnormal for any gas
operation; call for service.
NOTE
Normal burner flames look like Ex. 1 or 2.
If the flame looks like Ex. 3, do not use the
cooktop, and call for service.
2
6
English