![Dacor DOB30M977D series Installation Instructions Manual Download Page 33](http://html1.mh-extra.com/html/dacor/dob30m977d-series/dob30m977d-series_installation-instructions-manual_3401936033.webp)
English
33
Installation instructions
3-Wire Cable from Home Power Supply - U.S. Only
IMPORTANT:
Use the 3-wire cable from home power supply where local codes permit a
3-wire connection.
A
E
B
G
H
I
C
D
F
A.
Cable from home power supply
B.
Junction box
C.
Black wires (normally L1)
D.
White wires (normally N-neutral)
E.
green wires (normally G-ground)
F.
4-wire flexible conduit from oven
G.
Red wires (normally L2)
H.
UL listed wire connectors
I.
UL listed or CSA approved conduit
connector
1. Connect the 2 black wires (C) with a
UL-listed wire connector.
2. Connect the 2 white wires (D) and the
oven's green (bare) ground wire with
a UL-listed wire connector.
3. Connect the 2 red wires (G) with a
UL-listed wire connector.
4. Attach the junction-box cover.