Installation instructions
Installation instructions
4-Wire Cable from Home Power Supply
IMPORTANT:
Use the home power supply's 4-wire cable in:
•
The US (where local codes do not allow neutral grounding)
•
New branch circuit installations (1996 NEC)
•
Mobile homes and recreational vehicles
•
New construction
•
Canada.
A
E
B
G
H
I
C
D
F
A.
Cable from home power supply
B.
Black wires (normally L1)
C.
Red wires (normally L2)
D.
4-wire flexible conduit from oven
E.
Junction box
F.
White wires (normally N-neutral)
G.
UL listed wire connectors
H.
green wires (normally G-ground)
I.
UL listed or CSA approved conduit
connector
1. Connect the 2 black wires (B) with a
UL-listed wire connector.
2. Connect the 2 red wires (C) with a UL-
listed wire connector.
3. Untwist the white wire from the
oven's green (bare) ground wire .
4. Connect the 2 white wires (F) with a
UL-listed wire connector.
5. Connect the oven's green (bare)
ground wire (H) to the junction box's
green (bare) ground wire with a UL-
listed wire connector.
6. Attach the junction-box cover.