5
13 in max.
3
(33.0 cm)
3
Not applicable for cabinets more than a horizontal distance of 6 in.
(15.2 cm) from edge of cooktop. Allow 7 1/2 in
(19.1 cm) from edge
of cutout.
A
See cutout
dimensions
15 in min.
1
,
3
(45.7 cm)
1 7/8 in min.
(4.8 cm)
Combustible
surface to rear
Combustible overhead
cabinets
30 in min.
1
,
2
(76.2 cm)
7 1/2 in (19.1 cm) min. to
combustible side wall,
above counter (on both sides)
2
If installing with an overhead vent hood, also check hood
specifications for minimum required clearances.
1
Measured from top of cooktop grate.
All tolerances: +1/16” -0”
unless otherwise noted.
Cabinet/Countertop Layout
WARNING
• To reduce the risk of burn injury, avoid installing cabi-
nets above the cooktop.
• Not meeting or exceeding the maximum and minimum
dimensions/clearances in these instructions may result
in a fire hazard.
• Follow the countertop manufacturer’s instructions con-
cerning minimum corner radius, use of heat-reflective
tape, corner reinforcement, etc.
• For best performance, the cooktop should not be
placed where it can be affected by drafts (doors, win-
dows, heating and air-conditioning outlets).
• The cooktop is to be paired with a suitable vent hood or
approved Dacor downdraft.
CLEARANCE REQUIREMENTS
Model
A: Minimum
A: Recommended
DTCT304G
30 in (76.2 cm)
36 in (91.4 cm)
DTCT365G
36 in (91.4 cm)
42 in (106.7 cm)
DTCT466G
46 in (121.9 cm)
54 in (137.2 cm)
HPCT466G
46 in (121.9 cm)
54 in (137.2 cm)
Installation Specifications
Under-Chassis Clearance/Allowances
Allow at least 1/4” (6 mm) between the chassis bottom and
all combustible surfaces (incl. edges/corners of drawers
below the cooktop).
1/4” (6 mm)
min. clearance
to combustible
surfaces
B
Model
B (Min. clearance for hold-down brackets)
DTCT304G
29 in (73.7 cm)
DTCT365G
35 1/4 in (89.5 cm)
DTCT466G
45 1/4 in (114.64 cm)
HPCT466G
45 1/4 in (114.64 cm)
• Placement of gas-supply piping, gas shut-off valve, and
the electrical outlet must not impede cooktop installation.
• If installing an appliance below the cooktop, plan for rout-
ing of gas and power behind the appliance.
• The gas shut-off valve and regulator must remain acces-
sible after the unit is installed.
• The 40-in. (101.6 cm) power cord must reach an electri-
cal outlet; the outlet must be accessible after the cooktop
is installed.
• The chassis bottom must be accessible for service. (Do
not install a fixed shelf below the cooktop.)
• Leave space inside the cabinet for proper installation of
hold-down brackets.
See the following pages for countertop cutout dimensions.
Downdraft Compatibility
If installing the cooktop with a downdraft, use only these
approved Dacor model numbers:
Model
Corresponding Approved Downdraft Models
DTCT304G
ERV3015, PRV30, RV30
DTCT365G
ERV3615, PRV36, RV36
DTCT466G
PRV46, RV46
HPCT466G
PRV46, RV46
Summary of Contents for Distinctive DTCT365G
Page 18: ...16 Notes...
Page 19: ...17 Notes...