background image

All specifications subject to change without notice.

Phone: (800) 793-0093

www.dacor.com

PLANNING

GUIDE

DRT304S, DRT366S

Distinctive

  

30” and 36” Wide,

Slide-in Gas Rangetops

Document # PG04-003

Revised 10/17/14   Page 4/4

Stiffener

Cabinet face

Control panel

Countertop

Use Dacor down-

draft vent, model 

ERV3015 or

ERV3615 only

IMPORTANT: See downdraft

vent installation instructions for 

duct system layout/planning 

DRT series rangetop

3/8” min. (1.0 cm)

space behind

downdraft vent 

chassis to clear

stiffener

3/8” min. (1.0 cm)

flat countertop

overhang required  

behind cutout

Minimum

countertop 

height: 

30 1/4"

(76.8 cm)

28 5/16” (71.9 cm)

Non combustible rear 

wall recommended

10” (2.5 cm) min. to 

combustible wall 

above countertop, 

both sides

Cabinet face 

below countertop 

overhang

3/8” (1.0 cm) min. 

countertop overhang

2 5/8”

(6.7 cm)

Hole 1/2” dia. (1.3 cm), 

2 places, through platform

for hold down bolts 

1/2” (1.3 cm) 

countertop 

overhang

1” (2.5 cm) thick mounting platform min.

Open to below to allow for downdraft 

vent, gas and electrical connections

Countertop

Countertop

1/2” (1.3 cm) 

countertop 

overhang

2” (5.1 cm)

1” (2.5 cm)

15”

(38.1 cm)

24 1/2”

(62.2 cm)

D

E

D

F

B

CL

CABINET/COUNTERTOP CUTOUT 

DIMENSIONS WITH DOWN-

DRAFT VENT - TOP VIEW

CABINET/COUNTERTOP CUTOUT 

DIMENSIONS WITH DOWN-

DRAFT VENT - SIDE VIEW

Model No. B - Cutout 

Width

D

E

F - Vent 

Cutout

DRT304S 

with 

ERV3015*

30”  

(76.2 cm)

13 3/8” 

(34.0 cm)

10 1/8” 

(25.7 cm)

27 1/2” (69.9 

cm)

DRT366S 

with 

ERV3615*

36”  

(91.4 cm)

16 5/8”  

(42.2 cm)

11 3/16”  

(28.4 cm)

33 1/2” 

(85.1 cm)

* Use only downdraft vent model specified. Downdraft vent is not  

compatible with DRT rangetops having a serial number starting  

with letters “SA.”

Cutout tolerances: +1/16” (+1.6 mm), -0, unless otherwise stated

Cabinet and Countertop Layout (continued)

NOTE:

 Gas and electrical connections may only be routed through 

the bottom of the rangetop when installed with a downdraft vent.