background image

11

Installation Instructions

Installing the Glass Hood

 WARNING

Attaching the glass range hood requires two people. 

Do not attempt to lift the hood without assistance.

1.  Locate the hood mounting hardware. It consists of:

◊ 

4 thumb screws

◊ 

4 plastic washers

◊ 

4 plastic spacers

2.  For easier hood installation, assemble all the thumb 

screw hardware before lifting the hood into position.
•  Hold each thumb screw with the threads up.
•  Put the plastic washer on the thumb screw.
•  Put the plastic spacer over the end.

3.  Lift the glass hood into place. Line up the holes on 

the glass with the mounting holes on the bottom of 

the blower assembly.

4.  Insert all four thumb screws into the bottom of the 

glass  and tighten into place.

Installing the Chimney

5.  Carefully put the chimney over the blower assembly, 

taking care not to scratch the surfaces. Make sure 

the wiring is tucked in behind the chimney.

6.  Lock the tabs inside the chimney bottom into the slots 

on the bottom of the blower assembly.

7.  Slide the top of the chimney up toward the ceiling. 

Line  up the holes on the side of the chimney, near 

the vents, with the holes on the side of the chimney 

mounting bracket.

8.  Attach the top of the chimney to the mounting bracket 

using two sheet metal screws, one on each side.

Slots

Tabs on inside 

of chimney

Lock tabs 

on inside of 

chimney into 

slots on blower 

assembly

Chimney

Chimney mounting 

bracket

Summary of Contents for Discovery PHW Series

Page 1: ...Installation Instructions Discovery GlassWall Mount Range Hood PHW Model Series Part No 101745 Rev H...

Page 2: ...installation process Leave these installation instructions with the customer Customer Keep these installation instructions for future reference and the local electrical inspector s use If You Need Hel...

Page 3: ...G a Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer b Before servicing or cleaning unit switch power off at service panel and lock the serv...

Page 4: ...rfaces often to prevent grease fires and maintain performance If the cooktop and range hood are near a window use an appropriate window treatment Avoid long drapes or other window coverings that could...

Page 5: ...ation Contact your local building department for further information The minimum installed distance from the rear of blower unit base to the cooktop surface must be no less than 30 inches 76 2 cm 26 i...

Page 6: ...ceilings or into attics crawl spaces or garages To prevent combustion by products smoke or odors from entering the home and to improve efficiency tape all duct joints securely Do not exhaust more than...

Page 7: ...Work Design Tips Wherever possible reduce the number of transitions and turns to as few sharp angles as possible Two staggered 45 angles are better than one 90 Keep turns as far away from the hood exh...

Page 8: ...ure Replacement kit PN 101963 includes both chimney and blower mounting bracket Order the correct size see page 3 A A B C C B D D E F G G H H F E 8 20 cm WARNING Do not install the range hood unless t...

Page 9: ...7 Insert the two of the provided wall anchors into the holes on the ceiling 8 Place the chimney mounting bracket against the ceil ing and attach it using two included 1 1 2 screws Installing the Blowe...

Page 10: ...k or masonry Drill five 5 16 X 1 1 2 holes in the locations marked Insert five of the provided wall anchors into the five holes The anchors provided are for attaching the hood to masonry or brick only...

Page 11: ...er flaps on the top of the hood from opening 1 Inside the exhaust outlet on the top of the blower assembly there are metal or plastic damper flaps The flaps close to help prevent back drafts when the...

Page 12: ...fire hazard make sure the power supply at the fuse or junction box is turned off before proceeding with final installation Improper connection of the hood electrical wiring may create an electric shoc...

Page 13: ...on the bottom of the blower assembly 4 Insert all four thumb screws into the bottom of the glass and tighten into place Installing the Chimney 5 Carefully put the chimney over the blower assembly taki...

Page 14: ...d filled out completely and mailed Verifying Proper Operation 1 Turn on power at the junction or fuse box 2 If the control panel is not lit turn on the main power switch located next to the light fixt...

Page 15: ......

Page 16: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com...

Reviews: