All specifications subject to change without notice.
Phone: (800) 793-0093
www.dacor.com
PLANNING
GUIDE
B
A
C
D
DYRP36DS, DYRP48DS
Discovery 36” and 48” Wide
Dual Fuel Ranges
Document # PG05-010
Revised 09/03/14 Page 2/3
Electrical Requirements
■
The wiring needs to be long enough to allow the range to be pulled
out for service, while remaining connected.
The wiring to the range must:
►
Meet NEMA standards and have a minimum rating of 250 Volts
@ 30 Amps for model DYRP36DS and 250 Volts @ 50 amps for
model DYRP48DS
►
Include a strain relief
►
Be terminated by tinned leads, closed loop terminals or open
ended spade lugs with upturned ends
►
Connect to a junction box or receptacle installed by a licensed
electrician
The appliance may be connected one of the following ways:
Using conduit:
►
A 4-wire conduit connected to a 4-wire junction box, or
►
A 3-wire conduit (where local code permits, not for use with new
branch circuit installations) connected to a 3-wire junction box.
Using an appliance cord:
►
A 4-wire appliance cord equipped with a NEMA 14-50P plug
connected to a NEMA 14-50R receptacle, or
►
A 3-wire appliance cord (where local code permits) equipped with
a NEMA 10-50P plug connected to a NEMA 10-50R receptacle
►
Appliance cord plug must be UL listed type SRD or SRDT.
■
Range models DYRP36D-C-S and DYRP48D-C-S come with a
factory installed 4-wire appliance cord with NEMA 14-50P plug.
For freestanding ranges installed in Canada, a factory installed
4-wire appliance cord with NEMA 14-50P plug is required, without
modification.
NEMA 14-50P PLUG
NEMA 14-50P RECEPTACLE NEMA 10-50P RECEPTACLE
NEMA 10-50P PLUG
GAS SUPPLY PRESSURE REQUIREMENTS*
Gas Type
Manifold Pressure
Minimum Gas Supply
Pressure
Natural Gas
5” Water Column
6” Water Column
Propane (LP)
10” Water Column
11” Water Column
ELECTRIC CIRCUIT REQUIREMENTS
Range Model
Circuit Required
Total Connected Load
DYR36D[-C-]S
240 Vac*, 60 Hz, 30 Amp.
5.75 kW (24.0 Amp.)
DYR48D[-C-]S
240 Vac*, 60 Hz, 50 Amp.
10.1 kW (41.9 Amp.)
* 4-wire, two 120 Vac hot (L1 and L2), one neutral, one ground
The ratings above are for reference only. Refer to the range data label for
exact specifications.
Range electrical access,
cover removed
E Electrical connection
hole in bottom
Gas
inlet
Back of range
Gas Supply Requirements
■
The gas supply pressure for testing the regulator setting shall be
at least 1 inch water column (249 Pa) above the specified manifold
pressure.
■
Maximum gas supply pressure for all models: 1/2 psi.
■
The ratings above are for reference only. Refer to the range rating
label for exact specifications (see page II for location).
GAS - ELECTRICAL ACCESS DIMENSIONS
Model
A
B*
C
D
E**
DYRP36DS
6 3/4”
(17.1 cm)
27”
(68.6 cm)
12”
(30.5 cm)
6 3/4”
(17.1 cm)
7/8”
(2.2 cm)
DYRP48DS
4 1/4”
(10.8 cm)
27”
(68.6 cm)
9”
(22.9 cm)
6 3/4”
(17.1 cm)
7/8”
(2.2 cm)
* Measurement with appliance legs adjusted to lowest height.
** The diameter on models equipped for use in Canada is ¼” (6.4 mm)
larger than those stated. Canadian units come from the factory pre-wired
with an appliance cord. When installing an appliance cord on models that
are not pre-wired, the hole size must be increased to 1 1/8” (1 3/8” for
model ER48D) by removing the conduit bracket inside the range electrical
access box.