PLANNING

GUIDE

B

A

C

D

DYRP36DS, DYRP48DS

Discovery 36” and 48” Wide 

Dual Fuel Ranges

Document # PG05-010

Revised 09/03/14   Page 2/3

Electrical Requirements

 

The wiring needs to be long enough to allow the range to be pulled 

out for service, while remaining connected.

The wiring to the range must:

 

Meet NEMA standards and have a minimum rating of 250 Volts 

@ 30 Amps for model DYRP36DS and 250 Volts @ 50 amps for 

model DYRP48DS 

 

Include a strain relief

 

Be terminated by tinned leads, closed loop terminals or open 

ended spade lugs with upturned ends

 

Connect to a junction box or receptacle installed by a licensed 

electrician

The appliance may be connected one of the following ways:
        Using conduit:

 

A 4-wire conduit connected to a 4-wire junction box, or

 

A 3-wire conduit (where local code permits, not for use with new 

branch circuit installations) connected to a 3-wire junction box.

Using an appliance cord:

 

A 4-wire appliance cord equipped with a NEMA 14-50P plug 

connected to a NEMA 14-50R receptacle, or 

 

A 3-wire appliance cord (where local code permits) equipped with 

a NEMA 10-50P plug connected to a NEMA 10-50R receptacle

 

Appliance cord plug must be UL listed type SRD or SRDT. 

 

Range models DYRP36D-C-S and DYRP48D-C-S come with a 

factory installed 4-wire appliance cord with NEMA 14-50P plug. 

For freestanding ranges installed in Canada, a factory installed 

4-wire appliance cord with NEMA 14-50P plug is required, without 

modification.

NEMA 14-50P PLUG

NEMA 14-50P RECEPTACLE NEMA 10-50P RECEPTACLE

NEMA 10-50P PLUG

GAS SUPPLY PRESSURE REQUIREMENTS*

Gas Type

Manifold Pressure

Minimum Gas Supply 

Pressure

Natural Gas

5” Water Column

6” Water Column

Propane (LP)

10” Water Column

11” Water Column

ELECTRIC CIRCUIT REQUIREMENTS

Range Model

Circuit Required

Total Connected Load

DYR36D[-C-]S

240 Vac*, 60 Hz, 30 Amp.

5.75 kW (24.0 Amp.)

DYR48D[-C-]S

240 Vac*, 60 Hz, 50 Amp.

10.1 kW (41.9 Amp.)

* 4-wire, two 120 Vac hot (L1 and L2), one neutral, one ground
The ratings above are for reference only. Refer to the range data label for 

exact specifications.

Range electrical access, 

cover removed

E  Electrical connection 

    hole in bottom

Gas 

inlet

Back of range

Gas Supply Requirements

 

The gas supply pressure for testing the regulator setting shall be 

at least 1 inch water column (249 Pa) above the specified manifold 

pressure.

 

Maximum gas supply pressure for all models: 1/2 psi.

 

The ratings above are for reference only. Refer to the range rating 

label for exact specifications (see page II for location).

GAS - ELECTRICAL ACCESS DIMENSIONS

Model

A

B*

C

D

E**

DYRP36DS

6 3/4”

(17.1 cm)

27”

(68.6 cm)

12”

(30.5 cm)

6 3/4”

(17.1 cm)

7/8” 

(2.2 cm)

DYRP48DS

4 1/4”

(10.8 cm)

27”

(68.6 cm)

9”

(22.9 cm)

6 3/4”

(17.1 cm)

7/8” 

(2.2 cm)

* Measurement with appliance legs adjusted to lowest height.
** The diameter on models equipped for use in Canada is ¼” (6.4 mm) 

larger than those stated. Canadian units come from the factory pre-wired 

with an appliance cord. When installing an appliance cord on models that 

are not pre-wired, the hole size must be increased to 1 1/8” (1 3/8” for 

model ER48D) by removing the conduit bracket inside the range electrical 

access box.