V

erIfyIng

 p

aCkage

 C

onTenTs

D

esIgn

 s

peCIfICaTIons

•  Use & care manual

•  Steam barrier

•  2 glide assemblies

•  Metal shims

•  Mounting screws

•  Detergent tablets (sample)

•  Allen wrench (for grinder adjustment)

•  Decalcification powder (sample)

•  Measuring scoop

•  Cleaning brush

•  Filter holder

•  Filter - blind

•  Filter - single

•  Filter - double

•  Filter removal tool

•  Dispenser nozzle - single

•  Dispenser nozzle - double

•  Tamper

•  Teflon tubing (CM24PBISAS only)

•  Quick release connector kit: 1/4-16 BSPP male 

threaded connector and 3 piece 1/4” compression 

fitting (CM24PBISAS only)

A

: 23 1/2” (596mm) 

B

: 18 3/16” (462mm) 

C

: 20 3/4” (527mm)

I

nsTallaTIon

 s

peCIfICaTIons

Dimension tolerances: + 1/8”, - 0” unless otherwise stated.

o

Verall

 D

ImensIons

l

oCaTIon

 r

equIremenTs

NOTES:

1.  The electrical box and water shut off valve (for model 

CM24PBISAS) should be located in an adjacent 

cabinet.

2.  The electric cord is located in the lower right rear 

corner on the back of the unit.

3.  Do not install the unit in a free-standing cabinet.

4.  To prevent damage to the appliance, do not set it on 

the floor or counter prior to installation.

T

eChnICal

 s

peCIfICaTIons

Power Requirements

120V, 60Hz, 15A dedicated 

circuit required

Total Connected 

Load

1.4kW (12A)

Power Cord Length

60 inches

Appliance

Dimensions

Height: 18 3/16” (462mm)

Depth: 11 1/16” (281mm)

Width: 23 1/2” (597mm)

Unit Weight

72 lbs.

Shipping Weight

100 lbs.

Fresh Water Capacity

2.5 Liters/2.2 Quarts 

(Model CM24TBISAS only)

Minimum Regulated 

Input Pressure 

1.5 Bar (21.8 psi) at regulator 

output connection

Maximum Regulated 

Input Pressure

3.0 Bar (43.5 psi) at regulator 

output connection

•  Dacor

 

®

 cannot be held responsible for damage to 

property or injury to persons caused by failure to 

comply with the installation, maintenance, and safety 

instructions contained in this handbook.

•  Statutory regulations and the connection specifications 

issued by the local power supply company must be 

strictly observed.

•  The coffee system is supplied with a 60” (1524mm) 

long power cord terminated by a three-prong plug. The 

power cord is intended to be plugged directly into a 

dedicated, wall-mounted electrical receptacle.

•  The correct voltage, frequency, and amperage must be 

supplied to the electrical receptacle from a grounded, 

dedicated, single phase circuit that is protected by a 

properly sized circuit breaker or time-delay fuse. If one 

is not installed, call a licensed electrician.

•  The coffee system must be installed at a safe distance 

from other sources of heat, such as home appliances, 

in order to avoid an excessive rise in temperature.

B

E

F

D

D

A

B

C

D

: 17 3/8” (435mm) 

E

: 11 1/16” (281mm) 

F

: 3/16” (527mm)

Summary of Contents for CM24TBISAS

Page 1: ...Installation Instructions Semi Automatic Coffee System For use with models CM24TBISAS CM24PBISAS Part No 101985 Rev B...

Page 2: ......

Page 3: ...onal injury or property damage IMPORTANT INSTALLER In the interest of safety read these installation instructions completely before you begin the installation process Leave these installation instruct...

Page 4: ...th the controls or touch other parts of it Do not store items of interest to children on top of or above the coffee system Children could be burned or injured while climb ing on the appliance Do not t...

Page 5: ...se osmosis filtration system Reverse osmosis systems can cause low water pressure When the water pressure is low the coffee water volume level can fluctuate and the water pump may make a hammering sou...

Page 6: ...Cord Length 60 inches Appliance Dimensions Height 18 3 16 462mm Depth 11 1 16 281mm Width 23 1 2 597mm Unit Weight 72 lbs Shipping Weight 100 lbs Fresh Water Capacity 2 5 Liters 2 2 Quarts Model CM24...

Page 7: ...et cutout Attach it with the six 6 provided screws Steam Barrier Installation 22 1 8 22 3 8 562mm 568mm 3 4 19mm Level Support Platform Steam Barrier provided 3 4 19mm Min Side Walls 22 1 8 22 3 8 562...

Page 8: ...em slide into the cabinet guides The guide system allows the coffee system to slide in and out of the cabinet for loading the coffee bins and for maintenance To install the cabinet guides Determine th...

Page 9: ...ce s cover If they do not remove the machine and adjust the hooks up or down as needed You may adjust the force exerted by the safety brackets by adjusting the screws above and below the metal balls I...

Page 10: ...be installing the coffee system see page 3 If necessary have a qualified water treatment specialist install a water treatment system The water treatment system must be installed between the house plum...

Page 11: ...e bean container Any other kind of coffee e g coffee which has already been ground will damage the grinder Turn on the power switch The power indicator light will come on The system will automatically...

Page 12: ...m connected to or using only soft water 4gpg maximum hardness Has the coffee system been cleaned prior to use as specified in the use and care manual Is the coffee system connected to a dedicated grou...

Page 13: ...11 Notes...

Page 14: ...12 Notes...

Page 15: ......

Page 16: ...007 by Dacor Inc All rights reserved Specifications contained within are subject to change without notice No liability is assumed by DACOR for changes in specifications Web Site www Dacor com Phone 80...

Reviews: