DIGITAL INDICATOR
550A
20
(EXAMPLE)
When max. Capacity is set to 30.00kg whit 0.01kg division under functional setting to F04 - 02
t
The indicator will display an actual
Weight(variation of weight)
Setting of zero tracking range
F04
2
0
∫
3
The meaning of zero tracking?
In case of increasing the weight minutely by certain external
Facto(like Dust),this minute weight will be compensated to zero if it is
Within a flxed division and time
Auto – Zero setting
F05
00
00
∫
99
This is to make the weight of last two digits as to zero automatically
(To be applied for the disregarding of remaining weight in hopper, tanker
& etc)
※ (EXAMPLE)
if the indicator is set to 15kg/5g and F05-30,the range of auto zero will be 1~30g
At this time,F05 function is available up to 10% of full capacity
If the minute weight is 10g within a fixed
time(0,25sec)
But ,if the minute weight is
over10g within 0.25sec
1digit
(0.01Kg)
0.25 Sec
Summary of Contents for DN550A