DIGITAL INDICATOR
550A
18
6-2. F-FUNCTION LIST
F-Function
ITEM
CONTENTS
F00
Set-Up&Calibration
Clear or Enter Key
F01
Setting for position of decimal point
0, 0.0, 0.00, 0.000
F02
Back up of weight value
Normal, Back – UP
F03
Selection of MOTION BAND range
0~3
F04
Setting of ZERO TRACKING range
0~3
F05
AUTO ZERO setting
00∼99
F06
Digital filter
1∼9
F07
ZERO or TARE Key operation mode
0:Stable stage, 1:Unstable stage
F08
ZERO Key operation mode
2%(0), 5%(1), 10%(2), 20%(3)
F09
TARE Key operation mode
10%(0), 20%(1),50%(2),100%(3)
F21
Setting BIN range
1∼16
F22
Loose time of the weight finish
00∼99
F23
The next Weighing delay time
00∼99
F28
BIN, BATCH Choose the weight decision time
1∼99
F30
Setting of parity bit
0, 1,2
F31
Baue rate
0,1,2,3,4,5
F32
Transmission mode
0,1,2
F33
Communication mode
0, 1
F34
Identification mode
00∼99
F35
Selection of the data format mode
0, 1
F40
Select the unit of printing
0:g 1:㎏ 2:ton
F41
Printing Mode
0,1
F42
Printing type selection
0, 1
F43
Sub or Grand Data clear
0, 1
F44
Setting mode for line interval
1∼9
F45
Setting mode for line feed width
1∼9
F46
Setting mode for sub-total print
0,1
F50
Out-put logic
0,1
F80
Empty range
X X X
F89
Calibration SPAN constant
X.X X X X X
F90
Setting of data
X X . X X . X X
F91
Setting of time
X X . X X . X X