It is strongly recommended that ALL gate motor installations have infra-red beams connected as this is a
safety feature and will prevent the gate hitting a vehicle or pedestrian.
The wiring is done as shown above. It is important to check the following when installing beams.
The NC (normally closed ) connector is used on the beam. This is wired to the INF out-put on the main
P.C.Board.
The BEAMS jumper on the main PCBoard must be removed before the beams are fitted.
To de-activate the beams, place the BEAMS jumper over both pins. This will render the beams in-active
and will allow the gate to close regardless of any obstruction in front of the beams.
NOTE: D.A.C.E. will not be held liable for any damage to property or injury due to malfunction of safety
beams.
INF JUMPER on the
main PCBoard
To be removed before
beams are connected.
See page 13
MAIN P.C.BOARD
NB Beams shown with
front covers removed.
Covers must be in
place when beams are
active.
CONNECTING INFRA-RED BEAMS (OPTIONAL)
FIG 15
12 VOLT
GROUND
INF