SETTING UP THE 711 FEATURES.
Volume.
To adjust the volume of the speaker use the V+ and V- keys on
the rear of the phone. The volume once set will remain at the
user set level until it is re adjusted.
Call termination settings.
Call termination can be by pressing the off button on the front of
the telephone, by tone detection or preset timer.
Timer
To select preset timer place the link provided on the header
marked TMR TYPE on to the NRM setting, then select a duration
for maximum call length by adjusting the potentiometer marked
HK TIME (variable between 1 -10 minutes).
Tone detection
To select the tone detection option place the link provided on the
header marked TMR TYPE on to the MIC setting. This will
automatically clear the line at the end of a call by detecting the
tones on the line; additionally it will also monitor the
microphone. If there has been no activity on the microphone for
1 minute the telephone will automatically clear down.
Dialling modes
The telephone has selectable links for the different dialling and
recall modes. These are selected by placing the links onto the
relevant headers at the bottom of the board.
Dial modes
MF dialling- Take the link and place it onto the header marked
DIAL placing it on the MF link.
LD dialling- Take the link and place it onto the header marked
DIAL placing it on the LD link.
Recall modes
TBR recall- Take the link and place it onto the header marked
BREAK placing it on the TBR link.
ER recall- Take the link and place it onto the header marked
BREAK placing it on the ER link.
INSTALLATION
The following information is provided for use by the approved
installer or telephone network supplier only. The RA711
telephone can be either wall mounted or top-of-pole mounted.
Wall mounting can be surface, flush or inset into the wall.
Various electrical options are available as defined under the
Electrical Connections section. Make sure that these are set
correctly before finally fitting the unit to the back box.
Wall Flush Installation
1.
Produce hole in wall 285mm high 120mm wide 60mm
deep.
2.
Use size 8 or 10 screws with rawplugs (4 off) to fix back
box into wall, with cut-out at the bottom
3.
Connect the cabling, Use a 2.5mm socket-head key for
the M4 bolts, through the 4 small holes in the front plate,
to fit the telephone unit to the back-box. Start each screw
by turning several rotations at a time until all 4 screws
are secure. To remove the telephone from the box
reverse the procedure.
4.
Use any suitable silicone waterproofing sealant (such as
Unibond Waterproof Flexible Frame Sealant) to seal to the
wall. Leave a 12mm to 13mm (0.5") gap at the bottom
for drainage.