background image

ENGLISH

GB

11. TROUBLESHOOTING

FAULTS

CHECKS 

(possible causes)

REMEDIES

1

The  motor  does  not  start 

and does not produce noi-

se when the starting level is 

reached in the tank.

A. Supply failure.

B.

Check the protection fuses. (if also the new fuse burns

out, either the cable or the motor is faulty).

C.

Blocked impeller/grinder. (the thermal switch is off).

D.

Pressure switch pipe blocked.

A.

Reestablish the power supply.

B.

Replace the fuse.Measure cable and motor. If cable or

motor is defective, replace the defective parts.

C. 

Free the impeller/grinder, and wait until the motor is coo

-

led down and the thermal switch has reset.

D. 

Remove the pressure switch pipe and clean the pipe.

2

Motor  hums  but  does  not 

operate.

A.

Impeller/grinder stuck.

B. Motor or capacitor defective.

C. Control board defective.

A.

Free the impeller/grinder and check that it can rotate

freely.

B.

Replace the motor or capacitor.

C.

Replace the control board.

3

The  motor  works  conti

-

nuously or starts at regular 

intervals.

A. Water leaking from inlet into tank.

B.

Water leaking back into tank from discharge pipe.

C.

Pressure switch defective.

D.

Excess foam.

A.

Check for leaking appliances.

B.

Check the non-return flap.

C.

Replace the pressure switch unit.

D.

Check the air vent/ Check that the basin is connected

to the top connection / Provide an air vent (See Quick

Guide).

4

Motor runs but does not 

evacuate water.

A. Pump or tank blocked.

B.

Air lock in pump or vent hole in pump housing blo

-

cked.

A. Remove blockage.

B.

Check operation of vent valve in the tank.Check that

the carbon filter is not wet.

C.

Check that the vent hole in the pump housing is not

blocked.

5

The  service  station  drains 

slowly.

A.

Discharge pipe is too long or has an excessive num

-

ber of bends.

B.

The pump housing is leaky.

C. Hydraulics or grinder blocked.

A.

Increase discharge pipe size.Change pipework to re

-

duce number of bends.Change bends to soft bends.

B.

Replace the pump housing (servicepart).

C.

Check and clean the hydraulics and grinder.

6

Rattling noise from the lifting 

station, but water is evacua

-

ted.

A.

Foreign body hitting the impeller/grinder.

A.

Remove the foreign body.

7

Odour from the tank.

A.

Carbon filter contaminated.

A.

Replace the carbon filter.

14

Summary of Contents for GENIX

Page 1: ...GENIX ASENNUS JA HUOLTO OHJEET INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE INSTALLATIONS OCH UNDERH LLSANVISNING...

Page 2: ...page 9 sid 15 sivu 3 2...

Page 3: ...aa ammattimaisesti Turvallisuusm r ysten noudattamatta j tt misest on seurauksena henkil ihin ja laitteisiin kohdistuvia vaarati lanteita sek takuun raukeaminen Ammattitaitoinen henkil kunta On suosit...

Page 4: ...lisesti olevien ep tarkkuuksien osalta jos ne johtuvat paino tai j ljenn svirheist Valmistaja pid tt itselleen oikeuden tehd laitteisiin tarpeellisina tai hy dyllisin pit mi n muutoksia jotka eiv t he...

Page 5: ...in ei siirry t rin varmista ett putkisto ki innitet n riitt v sti eiv tk liitokset p se liikkumaan tai osumaan rakennuksen osiin WC istuimen ja pumppaamon v liset jatkoputket eiv t saa tukkeutumisrisk...

Page 6: ...tt porakoneen avulla 1 Katkaise s hk nsy tt 2 Jos tuotetta ei voida k ytt s hk virralla WC ja s ili voidaan tyhjent porakoneen avulla Kytke ensin j nnitesy tt irti Painekatkaisimen letku on tukossa 1...

Page 7: ...issa tiloissa joissa on vakaa ilmankosteus eik t rin ja p ly esiinny Ne toimitetaan alkuper isess pakkauksessa jossa niit on s ilytett v niiden asennushetkeen asti Mik li n in ei ole sulje imu ja pois...

Page 8: ...k y jatkuvasti tai k ynnistyy s nn llisin v liajoin A Vett vuotaa tuloliit nn st s ili n B Vett vuotaa takaisin s ili n paineputkesta C Painekytkin viallinen D Liikaa vaahtoa A Tarkasta mahdollisesti...

Page 9: ...ev ery right to assistance under guarantee Skilled personnel It is advisable that installation be carried out by competent skilled personnel in possession of the technical qualifications required by...

Page 10: ...the sewer by means of a natural downward slope The WCs and the other utilities connected to this system can be used normally and require minimum maintenance The system will operate automatically as s...

Page 11: ...s The product must be earthed The installation must include an earth leakage circuit breaker for protection against earth fault currents Thisensures protection when using a Schuko plug or another plug...

Page 12: ...6 Clean the rubber hose and check the opening on the tank Foreign body in tank 1 Disconnect the power supply 2 Unscrew the screw of the motor cover and remove the cover 3 If the water level is above...

Page 13: ...ecting the products to needless impacts and collisions 8 3 Weight The adhesive plate on the packaging indicates the total weight of the pump 9 MODIFICATIONS AND SPARE PARTS Any modification made witho...

Page 14: ...king from inlet into tank B Water leaking back into tank from discharge pipe C Pressure switch defective D Excess foam A Check for leaking appliances B Check the non return flap C Replace the pressure...

Page 15: ...sf reskrifterna g r att garantin bortfaller och kan orsaka skador p personer och appa rater Specialiserad personal Det rekommenderas att installationen utf rs av kompetent och kvalificerad personal so...

Page 16: ...ndas normalt och kr ver minimalt med underh ll Systemet b rjar att fungera automatiskt n r vattenniv n i tanken r tillr c klig 1 ANV NDNINGSOMR DEN Systemen Genix r endast avsedda f r behandling av a...

Page 17: ...6 UNDERH LL Systemet kr ver inget speciellt underh ll Vi rekommenderar dock att funktio nen och r rledningarnas kopplingar kontrolleras minst en g ng om ret 6 1 Inst llning av g ngtid per spolning St...

Page 18: ...r med en diameter p 20 7 TEKNISKA DATA Modell Hz Volt V P1 W Amp A Cos Max neds nkningsdjup Flow max m3 h Genix 50 220 240 490 2 3 0 95 0 91 8 0 6 9 60 115 60 127 Genix Comfort 50 220 240 490 2 3 0 95...

Page 19: ...ch alla tillbeh r m ste godk nnas av tillverkaren s att de kan garantera maximal s kerhet f r de maskiner och anl ggningar d r de ska monteras Om apparatens n tkabel skadas f r endast specialiserad pe...

Page 20: ...ten l cker tillbaka in i tanken fr n utloppsr ret C Tryckbrytare defekt D F r mycket skum A Kontrollera anslutna enheter med avseende p l ckor B Kontrollera backventilen C Byt ut tryckbrytarenheten D...

Page 21: ...1 1 1 2 1 3 21...

Page 22: ...1 2500 rpm 2 1 3 1 3 2 3 3 3 4 22...

Page 23: ...1 2 4 3 4 2 4 4 3 5 3 6 4 1 23...

Page 24: ...Clack 2 2 5 1 5 2 24...

Page 25: ...therlands dwtgroup com Tel 31 416 387280 Fax 31 416 387299 DAB PUMPS B V tHofveld 6 C1 1702 Groot Bijgaarden Belgium info belgium dwtgroup com Tel 32 2 4668353 DAB PUMPS IBERICA S L Calle Verano 18 20...