ENGLISH

GB

20

1.

.(<

The  frontispiece  shows  the  version  of  this  document  in  the  form  Vn.x. 
This version indicates that the document is valid for all software versions 
of the device n.y. For example: V3.0 is valid for all Sw: 3.y.

In  this  document  the  following  symbols  will  be  used  to  avoid  situations 
of ranger:

Situation of

 general danger.

 Failure to respect the instructions that 

follow may cause harm to persons and property.

Situation  of 

electric  shock  hazard

.  Failure  to  respect  the  instruc-

tions  that  follow  may  cause  a  situation  of  grave  risk  for  personal 
safety.

2.  GENERAL

Read this documentation carefully before installation.

Installation, electrical connection and commissioning must be carried out 
by specialised personnel, in compliance with the general and local safety 
regulations in force in the country in which the product is installed. Failure 
to respect these instructions not only causes risk to personal safety and 
damage to the equipment, but invalidates every right to assistance under 
guarantee.
The appliance is not intended to be used by persons (including children) 
with reduced physical, sensory or mental capacities, or who lack experi-
ence  or  knowledge,  unless,  through  the  mediation  of  a  person  respon-

VLEOHIRUWKHLUVDIHW\WKH\KDYHKDGWKHEHQH¿WRIVXSHUYLVLRQRURILQVWUXF

-

tions on the use of the appliance. Children must be supervised to ensure 
that they do not play with the appliance. 

Ensure  that  the  product  has  not  suffered  any  damage  during 
transport  or  storage.  Check  that  the  outer  casing  is  unbroken 
and in excellent conditions.

2.1  Safety

Use is allowed only if the electric system is in possession of safety pre-
cautions in accordance with the regulations in force in the country where 
the product is installed.

2.2  Responsibility

The Manufacturer does not vouch for correct operation of the machine or 
answer for any damage that it may cause if it has been tampered with, 

PRGL¿HGDQGRUUXQRXWVLGHWKHUHFRPPHQGHGZRUNUDQJHRULQFRQWUDVW

with other indications given in this manual.

INPUT POWER CABLE

INSTALL THE FERRITE CORE AS 
ILLUSTRATED

Summary of Contents for EVOPLUS D 120/220.32 M

Page 1: ...ET LA MAINTENANCE INSTRUCTIES VOOR INGEBRUIKNAME EN ONDERHOUD INSTRUCTIUNI DE INSTALARE SI INTRETINERE INSTALLATIONSANWEISUNG UND WARTUNG 16758 0217 8 216 5 1 92 1 328 7 5 8 1 92 1 1 7 8 5 8 MONTAJ VE...

Page 2: ...340 65 M B 120 340 65 M B 150 340 65 M B 40 340 65 SAN M B 60 340 65 SAN M B 80 340 65 SAN M B 100 340 65 SAN M B 120 340 65 SAN M B 150 340 65 SAN M D 40 340 65 M D 60 340 65 M D 80 340 65 M D 100 34...

Page 3: ...onal Differential Pressure depending on the Water Temperature 31 11 Control Panel 31 11 1 Graphic Display 31 11 2 Navigation Buttons 31 11 3 Warning Lights 31 12 Menus 32 13 Factory settings 34 14 Typ...

Page 4: ...the equipment but invalidates every right to assistance under guarantee The appliance is not intended to be used by persons including children with reduced physical sensory or mental capacities or who...

Page 5: ...a percentage of no more than 30 4 APPLICATIONS EVOPLUS series circulators allow integrated adjustment of the differ ential pressure which enables the circulator performance to be adapted to the actua...

Page 6: ...150 250 40 SAN M 15 0 25 65 D 150 250 40 M 15 0 46 17 B 180 250 40 M B 180 250 40 SAN M 18 0 25 65 D 180 250 40 M 18 0 46 17 B 40 240 50 M 4 0 20 27 D 40 240 50 M 4 0 36 49 B 60 240 50 M 6 0 25 20 D 6...

Page 7: ...M 4 0 67 14 B 60 360 80 M 6 0 43 54 D 60 360 80 M 6 0 78 37 B 80 360 80 M 8 0 42 84 D 80 360 80 M 8 0 77 11 B 100 360 80 M 10 0 49 02 D 100 360 80 M 10 0 88 24 B 120 360 80 M 12 0 58 12 D 120 360 80...

Page 8: ...Always switch off the mains power supply before working on the electrical or mechanical part of the system Wait for the war ning lights on the control panel to go out before opening the ap pliance The...

Page 9: ...es in the motor casing are not closed or partly blocked 7R JXDUDQWHH PD LPXP HI FLHQF RI WKH V VWHP DQG ORQJ OLIH RI WKH FLUFXODWRU LW LV UHFRPPHQGHG WR XVH PDJQHWLF VOXGJH UHPRYLQJ OWHUV WR separate...

Page 10: ...le leakage current selective protected against sudden tripping The automatic differential switch must be marked with the fol lowing two symbols The circulator does not require any external motor prote...

Page 11: ...puts and digital outputs so as to be able to realise interface solutions with more complex installations RU WKH LQVWDOOHU LW ZLOO EH VXI FLHQW WR ZLUH XS WKH GHVLUHG LQSXW DQG RXWSXW FRQWDFWV DQG WR F...

Page 12: ...stopped Closed Open Pump running with set point set by the user Closed Closed Pump running with reduced set point 8 2 2 MODBUS and LON Bus EVOPLUS circulators provide serial communication through an...

Page 13: ...arable voltage V 250 Max bearable current A 5 If resistive load 2 5 If inductive load Max accepted cable section mm 2 5 8 3 Connections for Twin Systems 3HU UHDOL DUH XQ VLVWHPD JHPHOODUH q VXI FLHQWH...

Page 14: ...LUS control panel see par 12 Page 2 0 10 1 1 Regulation with Proportional Differential Pressure In this regulating mode the differential pressure is redu ced or increased as the demand for water decre...

Page 15: ...e panel there are a graphic display 4 navigation keys and 3 LED warning lights see Figure 10 11 1 Graphic Display Using the graphic display it will be possible to navigate in an easy and intuitive men...

Page 16: ...tton then press and release the central button To modify the settings use the left and right buttons 7R FRQ UP WKH FKDQJH RI D VHWWLQJ KROG GRZQ WKH central button OK IRU VHFRQGV RQ UPDWLRQ ZLOO EH LQ...

Page 17: ...onomy operating mode Auto mode disables the reading of the status of digital input IN2 and in fact the system always activates the set point set by the user Economy mode enables the reading of the sta...

Page 18: ...a message in the language selected on Page 10 0 giving a brief description of the fault By pressing the right button you can scroll through all the pa ges of the log 2 questions appear at the end of...

Page 19: ...tly asked questions faq on the ecodesign directive 2009 125 ec establishing a framework for the setting of ecodesign requirements for energy related products and its implementing regulations http ec e...

Page 20: ...EVOPLUS B 40 240 50 M 0 23 EVOPLUS B 60 240 50 M 0 21 EVOPLUS B 80 240 50 M 0 21 EVOPLUS B 100 280 50 M 0 20 EVOPLUS B 120 280 50 M 0 19 EVOPLUS B 150 280 50 M 0 19 EVOPLUS B 180 280 50 M 0 19 EVOPLU...

Reviews: