DA DA1280 Manual Download Page 1

 

-1- 

 

DA1280  cordless telephone PLUG 

DECT and CAT-iq 

Manual 

Page

 

3

 

Start-Up with DECT GAP Basisstation

 

4

 

connect analog terminal 

5

 

operation : telephone,  Telefax 

6

 

operation : Hints 

7

 

switch into ex-works-setup  

8

 

change ex-works-setup parameters: Method 1 

9

 

Configuration Codes 

10

 

change ex-works-setup parameters: Method 2 

11

 

connectors, LED ,…           Software Upgrade 

12

 

Questions and Answers  (FAQ) 

13

 

Security Advices 

14

 

Warranty 

15

 

Recycling 

16

 

CE Conformity

 

 

Summary of Contents for DA1280

Page 1: ...rminal 5 operation telephone Telefax 6 operation Hints 7 switch into ex works setup 8 change ex works setup parameters Method 1 9 Configuration Codes 10 change ex works setup parameters Method 2 11 connectors LED Software Upgrade 12 Questions and Answers FAQ 13 Security Advices 14 Warranty 15 Recycling 16 CE Conformity ...

Page 2: ...but also to modern DSL VoIP Routers as Speedport from Deutsche Telekom or Fritzbox Tipel DSL VoIP Router or Internet Box from SwissCOM Simply connect your analog terminal via RJ11 cable to DA1280 RJ11 plug DA1280 will connect your terminal via DECT 30meter indoor with your access point which transmits your Call Fax or Data to your WAN destination All you have to do is to make your DA1280 acquainte...

Page 3: ...ABX and Multicell Systems DA1280 has a unique DECT ID called IPEI This IPEI you can see on the product label on your DA1280 It has is a 10 digit Hexadecimal form HEX Some DECT Systems e g PABX request this PIN in decimal form DEC The conversion HEX e g IPEI 00092268E9 into DEC form is as follows convert left sided 5 HEX digits into decimal 5 digits e g 00092HEX in 00146DEZ convert residual 5 HEX d...

Page 4: ...r is necessary You can immediately use your analogue terminal with DA1280 ex works setup See pages 8 10 if you need to adjust the ex works configuration Signalling tones description frequency tone pause dialling tone 440 Hz continous occupied 440 Hz periodically 125ms Ton 475ms pause special dialling tone 880 Hz continous positive execution signal 440 Hz 1 time 1 0 sec negative execution signal 44...

Page 5: ...k off analogue terminal LED3 shows active and dialing tone will be announced Analogue terminal dials calling number After 4 seconds wait DA1280 will setup the call with this resulting number sequence DA1280 is in transparent connection ex works setup Outgoing Call auto dialing DA1280 can hold a special telephone number for auto dialing after hook off This telephone number must be configured see pa...

Page 6: ...ng sequence Handset INT number possible Handset INT number are 1 2 3 5 6 7 8 9 Please notice that Internal Call enabled and transparent Mode on cannot be activated simultaneously If transparent Mode ON the DECT Link will be setup instantly after hook off DTMF tones will be transmitted and not processed ...

Page 7: ...flash time 300ms Auto dialling OFF restore ex works setup Press side key for 5 seconds to activate the RESET of DA1280 RESET function will restore the ex works setup All previous DECT registration will be deleted and all Settings will be reset to ex works parameters After RESET DA1280 will automatically start searching a DECT Base Station which is close to his place ...

Page 8: ...de 1 disconnect DA1280 from wall plug power OFF 2 hook off the phone which is connected to DA1280 3 connect DA1280 to wall plug again power ON You will hear the special signalling tone There is also Method2 to configure your DA1280 Here you connect DA1280 with your PC via USB cable A special DA1280 PC Application delivers a modern MMI for all Settings of DA1280 read more on page 10 ...

Page 9: ... 2 incoming calls 807 1 DTMF Signalling ON 807 0 DTMF Signalling OFF 808 DTMFsequence DTMF Signalling Sequence 2 digit 809 DTMF tone DTMF Signalling tone 1 digit 810 0 3 9 Flash Time 0 50ms 1 60ms 2 80ms 3 100ms 4 120ms 5 180ms 6 250ms 7 300ms 8 600ms 9 800ms 851 auto number Auto call number max 24 digit 852 1 Auto call ON 852 0 Auto call OFF 899 3853171 restore ex works setup Ex works parameters ...

Page 10: ...er you a comfortable MMI for all settings of DA1280 Adapt your setup to your requirements which will be automatically stored on DA1280 when closing the APP regularly 1 disconnect DA1280 from wall plug Power OFF 2 connect DA1280 to your PC via USB cable 3 download APP and start DA1280 APP 4 follow the instruction of the APP ...

Page 11: ...olors 3 LED3 active call in REP on off 4 side key Reset special for multicall HS 5 USB connector SW Upgrade Software Upgrade Software Upgrades for DA1280 can be downloaded via USB connector and USB cable to PC Please search your Supplier s website to get information about such Software Upgrades ...

Page 12: ...is not properly registrated to DECT BASE LED2 DECT Link is red DECT Base is switched OFF Execute Registration and take care about proper PIN of Base Reduce the position of DA1280 to Base till LED2 GRÜN Switch ON DECT Base and wait several seconds DECT Registration does not work DECT Base is not in Registration Mode PIN code is wrong Activate Registration Mode of DECT Base Use Registration via Conf...

Page 13: ...s Place DA1280 in wall sockets only with LEDs on top Protect your DA1280 from wet conditions dust and aggressive liquids and acrid fumes Use soft and wet wipes for cleaning the product Never use detergents Only qualified and authorised service personal are allowed to open and repair the product If you hand the product to further person do not forget to hand this manual with the product ...

Page 14: ...ir or replacement Returned and replaced products will pass its property to the Seller In case of defects Buyer has to immediately inform the Seller about such defects Warranty claims must be made evident via original receipt Any defect caused by incorrect handling usage and caused by physical stress or other incorrect environmental conditions are not subject to warranty claims ...

Page 15: ...your Dealer regarding Recycling of your product In no case get disposed of your product via household garbage Manual for DA1280 DECT analogue PLUG English Version 2 0 Edition 01 January 2017 Editor DOSCH AMAND Products GmbH München ...

Page 16: ...nts und des Rates zur Angleichung der Rechtsvorschriften der Mitgliedstaaten betreffend elektrische Betriebsmittel zur Verwendung innerhalb bestimmter Spannungsgrenzen The conformity with a m rules is confirmed by the CE sign The CE Conformity Declaration and Manufacturer s Declaration can be viewed under following address DOSCH AMAND Products GmbH Neumarkterstr 18 81673 München Technical Support ...

Reviews: