background image

6

Tensioned Cosmopolitan

®

 Electrol

®

 Installation

Screen Adjustment

The screen surface travel is stopped automatically in the fully opened and closed positions by limit switches that are properly  
adjusted at Da-Lite. The screen should not be adjusted for more or less drop. The fabric cables are adjusted for proper vertical  
and lateral tension at Da-Lite.

 

CAUTION! Contact Da-Lite at 800-622-3737 or 574-267-8101 if screen motor needs adjustment.

 

ATTENTION! Contactez Da-Lite au 800-622-3737 ou au 574-267-8101 au cas le moteur de l'écran a besoin d'être ajusté.

Low-Voltage Wall Switch

Optional IR and RF 

Remote Control

Splitter

Motor

Ground to Case

240VAC 50Hz

240V Wiring Diagram  

With Optional Built-In 

Low Voltage Control

Up

Stop

Down

Ground–Must be 
Connected to 
Building Ground

Green

Front

Back 

UP  DN

GND  +5V

3-Position 

Switch

RJ9

UP

+5V

 COM

DN

IMPORTANT NOTE: 

The wall switch is REQUIRED to make 

any limit switch adjustments, EVEN if a third party control 
system is used. Therefore, it is advised to wire the switch or 
provide a 4-conductor connection that is accessible.

Connect Supplied RJ9 Cable  
to Splitter and Switch, or use  

4 Cable Conductor to Connect  

to Screw Terminals.

ILT RJ9 Pin-Outs 

(Tab Is Facing Up)

Ground Common

IR or Up

+5V

DN or Data

Red

Green

White

Black

Green

Brown (Hot)

Blue (Common)

RJ9

RJ9

Dry Contacts

Summary of Contents for Tensioned Cosmopolitan Electrol

Page 1: ...INSTRUCTION BOOK FOR Tensioned Cosmopolitan Electrol For Sizes Up To 10 x 10 ...

Page 2: ...e manufacturer may cause a risk of fire electric shock or injury to persons Save These Instructions Pre Installation Installation NOTE Under no circumstances should unit be completely sealed in recessed installation Allow access for service Picture surface is centered in case Case extends 5 1 2 beyond surface on either end Do not attach anything to screen slat rod or bottom fabric pocket 1 Make su...

Page 3: ... Down Black Black Up White Red Down AC Hot Off Common White Black With Yellow Up Red Rocker Switch AC Common 120 V 60 Hz 2 5 Max Amp To Junction Box Mounted In Screen Case In Which Internal Wiring Terminates In White Black and Red Leads Motor End 3 4 Diameter Hole For Wall Installation Overall Length of Case Between Hanger Eyes Overall Length of Slat Slat Picture Surface Enclosure Cover 3 8 Diamet...

Page 4: ...witch Connect the BUS terminals on the wall switch to the corresponding BUS terminals on the splitter board IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party control system is used Therefore it is advised to wire the switch or provide a 3 conductor connection that is accessible RJ 14 Pin Outs Tab Is Facing Up Supplied RJ 14 cable Bus RP Data RQ D...

Page 5: ...deo Projector Interface 5 12 Volt Screen Trigger On Projector Ground Must Be Connected To Building Ground UP STOP DOWN Power Input 120VAC 60Hz Green Ground Black Hot White Common Power Wire Data Cable RJ 45 Jack RJ 45 Receptacle RJ 22 Output RJ 22 Jack RJ 22 Inputs RJ 22 Jack LED Up Limit Tactile Button Down Limit Tactile Button Front Of Wall Switch Back Of Wall Switch Black Red VPI Trigger Module...

Page 6: ... Low Voltage Wall Switch Optional IR and RF Remote Control Splitter Motor Ground to Case 240VAC 50Hz 240V Wiring Diagram With Optional Built In Low Voltage Control Up Stop Down Ground Must be Connected to Building Ground Green Front Back UP DN GND 5V 3 Position Switch RJ9 UP 5V COM DN IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party control syst...

Page 7: ...Replace motor assembly NOTE Motor is a sealed assembly Temporary binding With power off turn roller by hand to free binding Capacitor burned out Replace motor assembly Incorrect stopping position in downward direction Down limit switch out of adjustment Contact Da Lite at 800 622 3737 or 574 267 8101 Incorrect stopping position in upward direction Up limit switch out of adjustment Contact Da Lite ...

Page 8: ...MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES AS TO FITNESS FOR USE AND MERCHANTABILITY Any implied warranties of fitness for use or merchantability that may be mandated by statute or rule of law are limited to the one 1 year warranty period This warranty gives you specific legal rights and you may also have othe...

Reviews: