22
●
SYNC : In areas where the supply is at 60Hz, you can synchronize
the output phase of multiple cameras using the power synchronization
function (Line-Lock) without using a synchronization signal generator.
- INT : Internal Synchronization Type
- L/L : Power Synchronization Type, Line-lock
• Press the SET button.
• You can select a desired phase between 0 and 359.
☞
Note
• When using AC power at 60Hz frequency, you can use the L/L type synchronization.
• When the power is DC 12V, the SYNC. menu is fixed to the ‘INT’ mode.
●
MOTION DET:
If you connect an alarm device to this camera, you can monitor activity more efficiently, because
a signal is generated by the camera whenever motion is detected. The motion detection signal
is output through the MD OUT port.
①
When the SPECIAL menu screen is displayed, press the Up and Down buttons so that the arrow indicates
MOTION DET .
②
Set up the mode using the 4 direction buttons.
- SENSITIVITY : You can select up to 8 MD areas. When SENSITIVITY number is high, motion detection
sensitivity is increased to recognize even small movement.
- AREA MODE : Determines whether to use the MD area selected in SENSITIVITY.