background image

Model

DGS-3426P

DGS-3427

DGS-3450

Optional 10-Gigabit Uplink (Transceivers sold separately)

Single XFP Slot Module (DEM-410X)

Yes

Yes

Yes

Single CX4 Port Module (DEM-410CX)

Yes

Yes

Yes

10GBASE-SR (300 m Multi-Mode 

Fiber) Support

Yes

Yes

Yes

10GBASE-LR (10 km Single-Mode 

Fiber) Support

Yes

Yes

Yes

Maximum Number of 10-Gigabit 

Uplinks Installable

2

3

2

Performance

Switch Fabric

88Gbps

108Gbps

136Gbps

Packet Forwarding Rate

65.47Mpps

80.36Mpps

101.19Mpps

Packet Buffer

750KB

750KB

750KB

MAC Address Table

8K Entries

8K Entries

8K Entries

IP v4 Routing Table

128 Entries

128 Entries

128 Entries

IP v6 Routing Table

128 Entries

128 Entries

128 Entries

IP v4 Host Table

2K Entries

2K Entries

2K Entries

IP v6 Host Table

1K Entries

1K Entries

1K Entries

Jumbo Frame Size

9,216 Bytes

9,216 Bytes

9,216 Bytes

Power

Internal Power Supply

100 to 120VAC, 200 to 240VAC, 50/60Hz

100 to 120VAC, 200 to 240VAC, 50/60Hz

100 to 120VAC, 200 to 240VAC, 50/60Hz

Maximum Power Consumption

433 Watts

71.6 Watts

131.3 Watts

Optional Redundant Power Supply

DPS-600

DPS-500

DPS-500

Physical/Environmental

Ventilation

2 40x40mm DC Fans

2 40x40mm DC Fans

2 40x40mm DC Fans

Heat Dissipation

1477.48 BTU/Hr.

244.65 BTU/Hr.

448.02 BTU/Hr.

MTBF

98,704 hours

93,885 hours

78,517 hours

Acoustic

< 52.4dB

< 52.3dB

< 48.7dB

Operating Temperature

32° to 104°F (0° to 40°C)

32° to 104°F (0° to 40°C)

32° to 104°F (0° to 40°C)

Storage Temperature

-40° to 158°F (-40° to 70°C)

-40° to 158°F (-40° to 70°C)

-40° to 158°F (-40° to 70°C)

Operating Humidity

10% ~ 90% Non-condensing

10% ~ 90% Non-condensing

10% ~ 90% Non-condensing

Storage Humidity

5% ~ 90% Non-condensing

5% ~ 90% Non-condensing

5% ~ 90% Non-condensing

Dimensions

17.3 x 15.3 x 1.7 inches 

(441 x 389 x 44 mm)

19-inch Standard Equipment Rack 

Mount Width, 1U Height

17.3 x 15.3 x 1.7 inches 

(441 x 389 x 44 mm)

19-inch Standard Equipment Rack 

Mount Width, 1U Height

17.3 x 15.3 x 1.7 inches 

(441 x 389 x 44 mm)

19-inch Standard Equipment Rack 

Mount Width, 1U Height

Weight

12.8 lbs (5.82 kg)

12.1 lbs (5.51 kg)

11.6 lbs (5.27 kg)

Emissions

FCC Class A, CE, C-Tick, VCCI

FCC Class A, CE, C-Tick, VCCI

FCC Class A, CE, C-Tick, VCCI

Safety Compliance

CSA International, CB

CSA International, CB

CSA International, CB

xStack

®

 DGS-3400 Series (DGS-3426P, DGS-3427, and DGS-3450)

Summary of Contents for xStack DGS-3426P

Page 1: ...nal 10 Gigabit uplinks All three models support four combo SFP ports which means that when these ports are enabled four of the copper gigabit ports will be disabled When stacked the xStack DGS 3400 Series has a stacking backplane of 40Gbps Advanced Network Security For edge network security the DGS 3400 Series supports features such as IP MAC Port Binding to prevent security breaches such as rogue...

Page 2: ...stream control which allows a service provider to assign limited multicast addresses per port This means it can act asasecuritycontrolthatpre configureschannelsforeach subscriber on a port level to prevent unauthorized hosts from receiving traffic for a multicast group they have not joined The xStack DGS 3400 Series also supports IGMP multicast VLAN which eliminates duplicate multicast traffic bei...

Page 3: ...nal Redundant Power Supply DPS 600 DPS 500 DPS 500 Physical Environmental Ventilation 2 40x40mm DC Fans 2 40x40mm DC Fans 2 40x40mm DC Fans Heat Dissipation 1477 48 BTU Hr 244 65 BTU Hr 448 02 BTU Hr MTBF 98 704 hours 93 885 hours 78 517 hours Acoustic 52 4dB 52 3dB 48 7dB Operating Temperature 32 to 104 F 0 to 40 C 32 to 104 F 0 to 40 C 32 to 104 F 0 to 40 C Storage Temperature 40 to 158 F 40 to ...

Page 4: ...6 Flow Label TCP UDP Port User Defined Packet Content2 Access Control Lists ACL Up to 768 Access Rules Switch Port MAC Address 802 1p Priority VLAN Protocol Type TOS DSCP IP Address IP v 4 v 6 Address IP v 6 Traffic Class IP v 6 Flow Label TCP UDP Port User Defined Packet Content2 Time based ACL CPU Interface Filtering ACL Statistic2 Security RADIUS TACACS TACACS SSH v 2 SSL v 3 Port Security 802 ...

Page 5: ...Redundant Power Supply Unit 500 Watt RPSU for DGS 3426P DPS 800 2 Slot RPSU Open Chassis for DPS 200 DPS 500 DPS 900 8 Slot RPSU Open Chassis for DPS 200 DPS 500 DV 600S D View 6 0 Network Management Software Standard Version DV 600P D View 6 0 Network Management Software Professional Version D LinkSystems Inc 17595Mt HerrmannStreetFountainValleyCA92708www dlink com 2008 2009 D Link Corporation D ...

Reviews: