background image

DXS-3600 Series 10GbE Layer 2/3 Switch Web UI Reference Guide

14

Traffic Monitoring by Type

This page can be used to monitor traffic, per-port, of a certain 

type

After selecting a 

Port

 number and then selecting the 

Type

 option, from the drop-down menu, click the 

Apply

 button to 

view the page below:

The following parameters can be configured on this page:

Click the 

Apply 

button to accept the changes made.

Parameter

Description

Port

Select the port number used here. 

View By

Select the view type used here. This list of options to choose from are 

Direction

Type

Size

, and 

Error

. For this page, select 

Type

.

Traffic Type

Select the type of traffic to monitor here. The list of options to choose from are 

Multicast

Broadcast

Unicast

, and 

All

. Selecting the 

All 

option will display all the 

types of traffic supported by this switch.

Summary of Contents for DXS-3600 Series

Page 1: ...Web UI Reference Guide Product Model DXS 3600 Series Layer 2 3 Managed 10GbE Switch Release 1 10...

Page 2: ...radiate radio frequency energy and if not installed and used in accordance with this manual may cause harmful interference to radio communications Operation of this equipment in a residential area is...

Page 3: ...used to put emphasis on a key subject in a sentence through out this manual This font is also used to represent the physical CLI command used when explaining a topic Boldface Typewriter Font This font...

Page 4: ...C powered option intended for your system purchase a power cable that is approved for use in your country The power cable must be rated for the product and for the voltage and current marked on the pr...

Page 5: ...rge Static electricity can harm delicate components inside the system To prevent static damage discharge static electricity from your body before touching any of the electronic components such as the...

Page 6: ...eb User Interface 2 Logging onto the Web Manager 2 Areas of the User Interface 3 Switch Status 5 Device Information 6 Temperature Status 7 CPU Status 8 System Log Entries 9 Fan Status 11 Flash SD Card...

Page 7: ...crosoft Internet Explorer version 6 0 and later Mozilla Firefox version 3 0 and later Safari version 4 0 and later Google Chrome version 5 0 and later Opera version 9 0 and later and Netscape version...

Page 8: ...lable in the Web based manager are explained below Areas of the User Interface After a successful connection to the Web User Interface has been made the following page should be displayed NOTE To be a...

Page 9: ...some of the hardware features run ning on this switch Some of the features that can be monitored here are the Device Information Temperature CPU Usage System Log Fan Status Memory Usage and Network Tr...

Page 10: ...UI Reference Guide 5 Switch Status Device Information Temperature Status CPU Status System Log Entries Fan Status Flash SD Card and Memory Status After clicking on the Switch Status link found in the...

Page 11: ...s displayed Subnet Mask Here the Subnet Mask of the switch s main interface is displayed Gateway Here the Gateway IP address of the switch s main interface is displayed MAC Address Here the MAC addres...

Page 12: ...in that automatically controls the air flow inside the switch In the Temperature section the following display parameters are available Parameter Description Percentage Display In this graphic the rea...

Page 13: ...ere is an abundance of features that can be enabled to prevent this problem from occuring In the CPU section the following display parameters are available Parameter Description Percentage Display In...

Page 14: ...available Click the More button to view a larger display of the complete System Log section Click the Close button to exit the larger display Parameter Description Entry Number Every log entry has a...

Page 15: ...DXS 3600 Series 10GbE Layer 2 3 Switch Web UI Reference Guide 10...

Page 16: ...lay parameters are available Parameter Description Fan Number At the top of this graphic the list of installed fans are displayed After clicking on any specific fan icon the real time RPM gauge of tha...

Page 17: ...e Parameter Description Used This displays the color that represents the used memory allocation Flash This displays the used and unused space of the Flash The more accurate percentage display can be f...

Page 18: ...ons that can by selected are received Rx or transmited Tx packets After selecting a Port number and then selecting the Direction option from the drop down menu click the Apply button to view the page...

Page 19: ...g parameters can be configured on this page Click the Apply button to accept the changes made Parameter Description Port Select the port number used here View By Select the view type used here This li...

Page 20: ...nfigured on this page Click the Apply button to accept the changes made Parameter Description Port Select the port number used here View By Select the view type used here This list of options to choos...

Page 21: ...used here This list of options to choose from are Direction Type Size and Error For this page select Error Direction Select the traffic flow direction to monitor here The list of options to choose fr...

Page 22: ...to date will prevent any future inconvenience caused by minor software bugs Also from time to time D Link provides new features that can only be acquired with a new firmware update Keeping a copy of...

Page 23: ...ction the following can be seen The following parameters can be configured in this section Parameter Description Destination File Enter the location and name of the Destination File Source File Enter...

Page 24: ...DXS 3600 Series 10GbE Layer 2 3 Switch Web UI Reference Guide 19 Click the Upload button to initiate the upload...

Page 25: ...port of the device It is necessary for the user needs to attach a terminal or PC with terminal emulation to the console port of the switch 2 Power on the Switch After the UART init is loaded to 100 t...

Page 26: ...n The user s session Username Represent current login user Ipaddr Represent client IP address macaddr Represent client MAC address Informational Event description Firmware upgrade was unsuccessful Log...

Page 27: ...ername Represent current login user Ipaddr Represent client IP address macaddr Represent client MAC address Informational Event description Configuration upload was unsuccessful Log Message TFTP 8 Con...

Page 28: ...s of the TELNET client username The user name that used to login to the TELNET server Warning Event description Logout from TELNET Log Message Logout from TELNET Username username IP ipaddr Parameters...

Page 29: ...n ipaddr The IP address of the RADIUS server vlanID The VID of the RADIUS assigned VLAN interface id The interface name Username The user that is being authenticated Informational Event description Th...

Page 30: ...ure at port interface id string Parameters description ipaddr The IP address of the RADIUS server interface id The interface name Username The user that is being authenticated string The failed RADIUS...

Page 31: ...4 5 interfaceName 5 6 agentCircuitId 6 7 local 7 portID The port ID deviceClass The LLDP MED device type Notice Event description Incompatible LLDP MED TLV set detected Log Message Incompatible LLDP...

Page 32: ...efined error code or sub error code in RFC 4271 Log Message BGP 4 BGP Notify unkown Error code num Sub Error code num Peer ipaddr Parameters description num The Error Code or Error Subcode defined in...

Page 33: ...from new 4 bytes AS peer Peer ipaddr Parameters description ipaddr The IP address of the BGP peer Warning Event description BGP received AS_CONFED_SEQUENCE or AS_CONFED_SET path segment type in AS4 P...

Page 34: ...nterface administrator state changed Log Message OSPF protocol on interface intf name changed state to Enabled Disabled Parameters description intf name The name of the OSPF interface Informational Ev...

Page 35: ...Loading to Full Parameters description nbr id Neighbor s router ID Notice Event description One OSPF virtual neighbor state changed from Full to Down Log Message OSPF nbr nbr id on virtual link change...

Page 36: ...ect checksum on VR vr id at interface intf name Parameters description vr id The VRRP virtual router ID intf name The virtual router s interface name Warning Event description Virtual router ID mismat...

Page 37: ...ion vrrp mac addr The VRRP virtual MAC address vrrp errcode The error code of the VRRP protocol behaviour Error Event description Failed when adding a virtual MAC into the switch s L3 table The L3 tab...

Page 38: ...c addr from the switch s L3 table Errcode vrrp errcode Parameters description vrrp ip addr The VRRP virtual IP address vrrp mac addr The VRRP virtual MAC address vrrp errcode The error code of the VRR...

Page 39: ...dr The IP address username The user name Warning Event description Logout Log Message Logout through Console Telnet Web SSL SSH Username username IP ipaddr Parameters description ipaddr The IP address...

Page 40: ...paddr authenticated by AAA local server ipaddr Username username Parameters description local Enable admin by AAA local method server Enable admin by AAA server method ipaddr The IP address username T...

Page 41: ...to a packet storm Log Message interface id is currently shut down due to a packet storm Parameters description interface id The interface name Warning MSTP Debug Event description Topology changed Log...

Page 42: ...tance ID Informational Event description Spanning Tree Version changed Log Message Spanning Tree version changed New version new_version Parameters description new_version The new STP version Informat...

Page 43: ...ense model AC string25 Parameters Description license model The license model name string25 The activation code Critical Event Description License successfully installed Log Message License successful...

Page 44: ...P ID Informational Event description LSP is down Log Message LSP lsp_id is down Parameters description lsp_id The deleted LSP ID Informational VPWS Event description Pseudowire link down Log Message P...

Page 45: ...ption vpls_name The name of the link down VPLS Informational LACP Event description Link Aggregation Group link up Log Message Link Aggregation Group group_id link up Parameters description group_id T...

Page 46: ...Topology Change Timer immediately subsequent to its election Implementation of this trap is optional 1 3 6 1 2 1 17 0 1 topologyChange A topologyChange trap is sent by a bridge when any of its config...

Page 47: ...6 1 2 1 16 0 2 MPLS mplsXCUp This notification is generated when the mplsXCOperStatus object for one or more contiguous entries in the mplsXCTable is about to enter the up state from another state 1...

Page 48: ...d by the included value of ifOperStatus Binding objects 1 ifIndex 2 if AdminStatus 3 ifOperStatus 1 3 6 1 6 3 1 1 5 4 linkDown A linkDown trap signifies that the SNMP entity acting in an agent role ha...

Reviews: